background image

6

 | 

Energy saving and optimum operation

User reference guide

27

FTXTP-M_FTXTP-N
Daikin room air conditioners
4P728152-3 – 2023.03

6 Energy saving and optimum operation

INFORMATION

Even if the unit is turned OFF, it consumes electricity.

When  the  power  turns  back  on  after  a  power  break,  the  previously  selected
mode will be resumed.

CAUTION

NEVER expose little children, plants or animals directly to the airflow.

NOTICE

Do  NOT  place  objects  below  the  indoor  and/or  outdoor  unit  that  may  get  wet.
Otherwise  condensation  on  the  unit  or  refrigerant  pipes,  air  filter  dirt  or  drain
blockage may cause dripping, and objects under the unit may get dirty or damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air  conditioner  and  do  NOT  use
sprays near the unit. Doing so may result in a fire.

CAUTION

Do  NOT  operate  the  system  when  using  a  room  fumigation-type  insecticide.
Chemicals  could  collect  in  the  unit,  and  endanger  the  health  of  people  who  are
hypersensitive to chemicals.

Observe the following precautions to ensure the system operates properly.

Prevent direct sunlight from entering a room during cooling operation by using
curtains or blinds.

Make sure the area is well ventilated. Do NOT block any ventilation openings.

Ventilate often. Extended use requires special attention to ventilation.

Keep doors and windows closed. If the doors and windows remain open, air will
flow out of your room causing a decrease in the cooling or heating effect.

Be careful NOT to cool or heat too much. To save energy, keep the temperature
setting at a moderate level.

NEVER place objects near the air inlet or the air outlet of the unit. Doing so may
cause a reduced heating/cooling effect or stop operation.

Turn the breaker off when the unit is NOT used for longer periods of time. If the
breaker is on, the unit consumes electricity. Before restarting the unit, turn the
breaker on 6 hours before operation to ensure smooth running.

Condensation may form if the humidity is above 80% or if the drain outlet gets
blocked.

Adjust  the  room  temperature  properly  for  a  comfortable  environment.  Avoid
excessive  heating  or  cooling.  Notice  that  it  may  take  some  time  for  the  room
temperature  to  reach  the  set  temperature.  Consider  using  the  timer  setting
options.

Adjust the air flow direction to avoid cool air from gathering on the floor or warm
air  against  the  ceiling.  (Up  during  cooling  or  dry  operation  to  the  ceiling  and
down during heating operation.)

Avoid direct air flow to room inhabitants.

Summary of Contents for Comfora FTXTP-M

Page 1: ...User reference guide Daikin room air conditioners FTXTP25M5V1B FTXTP35M5V1B FTXTP25N5V1B FTXTP35N5V1B...

Page 2: ...rt airflow operation 21 5 6 1 To start stop Comfort airflow operation 22 5 7 Powerful operation 22 5 7 1 To start stop Powerful operation 22 5 8 Econo operation 23 5 8 1 To start stop Econo operation...

Page 3: ...tion or idle time is heard 38 8 1 6 Symptom A clapping sound is heard 38 8 1 7 Symptom White mist comes out of a unit Indoor unit 38 8 1 8 Symptom The units can give off odours 38 8 1 9 Symptom The ou...

Page 4: ...ting your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructi...

Page 5: ...nor or moderate injury NOTICE Indicates a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explan...

Page 6: ...hysical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards i...

Page 7: ...human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste...

Page 8: ...sent Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before resuming operation CAUTION ALWAYS use the wireless remote control or other user int...

Page 9: ...materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless WARNING The appliance shall be st...

Page 10: ...ge Splashed detergent on electric components such as motors may cause failure smoke or ignition DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the breaker OFF or pull...

Page 11: ...TION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may cause an electrical shock...

Page 12: ...utomatic 3 2 About the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface This manual describes only operation with...

Page 13: ...f j i h g a a Signal receiver b OFF button c Fan setting button d Econo operation button e Swing buttons f Timer setting buttons ON OFF cancel g Powerful operation button h Comfort operation button i...

Page 14: ...gh Airflow rate Medium Airflow rate Medium low Airflow rate Low Comfort operation is active Automatic vertical swing is active Automatic horizontal swing is active ON timer is active OFF timer is acti...

Page 15: ...control Fixing the wireless remote control to the wall Turning on the power supply 4 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Insert both batteries...

Page 16: ...erence guide 16 FTXTP M_FTXTP N Daikin room air conditioners 4P728152 3 2023 03 4 4 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to...

Page 17: ...mperature 18 32 C DB 14 23 C WB 10 30 C DB Indoor humidity 80 b a A safety device might stop the operation of the system if the unit runs outside its operation range b Condensation and water dripping...

Page 18: ...user selection Setting Description Automatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system...

Page 19: ...ne or more times to set the temperature You CANNOT adjust the temperature in drying or fan only operation mode Cooling operation Heating operation Automatic operation Drying or fan only operation 18 3...

Page 20: ...blades louvers Setting Airflow direction Vertical automatic swing Moves up and down Horizontal automatic swing Moves from side to side 3 D airflow direction Moves alternately up and down and from sid...

Page 21: ...from the wall Efficiency will drop if a wall blocks the air 5 5 3 To use 3D airflow direction 1 Press and Result and appear on the LCD The flaps horizontal blades and louvers vertical blades will beg...

Page 22: ...y Mode Airflow rate Cooling Heating To maximize the cooling heating effect the capacity of outdoor unit is increased The airflow rate is fixed to the maximum setting The temperature and airflow settin...

Page 23: ...operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption...

Page 24: ...s operating operation will stop after 5 hours 3 To cancel the setting press Result and the time setting disappear from the LCD and the timer lamp goes off INFORMATION Night set mode When the OFF timer...

Page 25: ...t to your home network and download the app to change the thermostat set temperature schedules review your energy consumption and more For details on specifications setting methods FAQ troubleshooting...

Page 26: ...3 03 5 10 2 To install the ONECTA app 1 Go to Google Play for Android devices or the App Store for iOS devices and search for ONECTA 2 Follow the directions on the screen to install the ONECTA app INF...

Page 27: ...ins or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed If the do...

Page 28: ...timum operation User reference guide 28 FTXTP M_FTXTP N Daikin room air conditioners 4P728152 3 2023 03 Operate the system within the recommended temperature range 26 28 C for cooling and 20 24 C for...

Page 29: ...the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation...

Page 30: ...mote control WARNING Improper detergents or cleaning procedure may cause damage on plastic components or water leakage Splashed detergent on electric components such as motors may cause failure smoke...

Page 31: ...4 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 5 About the air filters Operating the unit with dirty filters means that the filter CANNOT deodorise the...

Page 32: ...sily wash them with a neutral detergent diluted in lukewarm water Dry the air filters in the shade It is recommended to clean the air filters every 2 weeks 7 7 To clean the titanium apatite deodorisin...

Page 33: ...old filter as non flammable waste To order titanium apatite deodorising filter or silver particle filters contact your dealer Item Part number Titanium deodorising filter KAF970A46 Silver particle fil...

Page 34: ...INFORMATION It is recommended to have periodical maintenance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the customer In certain operat...

Page 35: ...ce User reference guide 35 FTXTP M_FTXTP N Daikin room air conditioners 4P728152 3 2023 03 7 10 1 Winter season Only for RXTP R NOTICE Remove any icicles on the outdoor unit Use gloves to avoid injury...

Page 36: ...te control To display the error code see 8 2 Solving problems based on error codes 439 Notify your installer and report the error code If the system does NOT operate properly except for the above ment...

Page 37: ...erates in Econo operation Refer to 5 8 Econo operation 423 Check if there is any furniture directly under or next to the indoor unit Move the furniture An abnormal function happens during operation Th...

Page 38: ...sound during operation or idle time is heard This sound is generated when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is generated wh...

Page 39: ...er INFORMATION See the service manual for The complete list of error codes A more detailed troubleshooting guideline for each error To check the error code by the wireless remote control 1 Aim the wir...

Page 40: ...ty Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise Inverter in...

Page 41: ...e RUN LED is lit make sure that the smartphone or tablet is connected to the same wireless LAN network as the Wireless LAN adapter When trying to make a direct connection to the adapter AP mode the Wi...

Page 42: ...28152 3 2023 03 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units M...

Page 43: ...rvice to the product Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual speci...

Page 44: ...TANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 4P728152 3 2023 03 Copyright 20...

Reviews: