When the Need Arises

Before making an inquiry or a request for repair, please check the following.
If the problem persists, consult your dealer.

Not a problem

This case is not a problem.

Check

Please check again before requesting 

repairs.

Case

Description / what to check

Operation does not start soon.

• When ON/OFF button was pressed 

soon after operation was stopped.

• When the mode was reselected.

• 

This is to protect the air conditioner.

You should wait for about 3 minutes.

Air does not come out.

 

„

In HEAT operation

•  The air conditioner is warming up. Wait for about 1 to 4 minutes.
•  During defrosting operation, hot air does not fl ow out of the indoor unit.

 

„

When the air conditioner operates immediately after the circuit breaker is turned on

•  The air conditioner is preparing to operate. Wait for about 3 to 20 minutes.

The heating operation stops suddenly 

and a fl owing sound is heard.

•  The system is taking away the frost on the outdoor unit.

You should wait for about 4 to 12 minutes.

The outdoor unit emits water or 

steam.

 

„

In HEAT mode

• 

The frost on the outdoor unit melts into water or steam when the air conditioner is in 
defrost operation.

 

„

In COOL or DRY mode

• 

Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips.

Mist comes out of the indoor unit.

 

„

This happens when the air in the room is cooled into mist by the cold air fl ow during cooling 

operation.

The indoor unit gives out odour.

 

„

This happens when smells of the room, furniture, or cigarettes are absorbed into the unit 

and discharged with the air fl ow.
(If this happens, we recommend you to have the indoor unit washed by a technician. 

Consult the service shop where you bought the air conditioner.)

The outdoor fan rotates while the 

air conditioner is not in operation.

 

„

After operation is stopped:

•  The outdoor fan continues rotating for another 30 seconds for system protection.

 

„

While the air conditioner is not in operation:

•  When the outdoor temperature is very high, the outdoor fan starts rotating for system protection.

The operation stopped suddenly.

(OPERATION lamp is on.)

 

„

For system protection, the air conditioner may stop operating on a sudden large voltage fl uctuation.
It automatically resumes operation in about 3 minutes.

The air conditioner does not 

operate.

(OPERATION lamp is off.)

•  Hasn’t a breaker turned OFF or a fuse blown?
•  Isn’t it a power failure?
•  Are batteries set in the remote controller?
•  Is the timer setting correct?

Cooling (Heating) effect is poor.

•  Are the air fi lters clean?
•  Is there anything blocking the air inlet or the outlet of the indoor and the outdoor units?
•  Is the temperature setting appropriate?
•  Are the windows and doors closed?
•  Are the air fl ow rate and the air direction set appropriately?

Operation stops suddenly.

(OPERATION lamp fl ashes.)

•  Are the air fi lters clean?
•  Is there anything blocking the air inlet or the outlet of the indoor and the outdoor units? 

Clean the air fi lters or take all obstacles away and turn the breaker OFF. Then turn it ON 
again and try operating the air conditioner with the remote controller. If the lamp still blinks, 

call the service shop where you bought the air conditioner.

•  Are operation modes all the same for indoor units connected to outdoor units in the 

multi system?

If not, set all indoor units to the same operation mode and confi rm that the lamps blink.
Moreover, when the operation mode is in “AUTO”, set all indoor unit operation modes to 
“COOL” or “HEAT” for a moment and check again that the lamps are normal.
If the lamps stop blinking after the above steps, there is no malfunction.

Troubleshooting

01_EN_3P472684-5A.indd   9

7/3/2017   5:20:08 PM

Summary of Contents for CDXM25RVMA

Page 1: ...joy year round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS CDXP25RVMA CDXP35RVMA CDXM25RVMA CDXM35RVMA CDXM50...

Page 2: ...for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour The appliance must be installed operated a...

Page 3: ...unattended young children or infirm persons Impairment of bodily functions and harm to health may result Children should be supervised to ensure that they do not play with the unit or its remote contr...

Page 4: ...amp is not used Indoor temperature sensor Detects the air temperature around the unit TIMER lamp orange OPERATION lamp green Indoor unit ON OFF switch Press this switch once to start operation Press o...

Page 5: ...with the remote controller Wired remote controller Wireless remote controller Outdoor Unit The appearance of the outdoor unit may differ between different models Earth terminal inside Refrigerant pip...

Page 6: ...next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during installation Please consult your retailer or dealer for assistance NIGHT QUIET mode r...

Page 7: ...mode in room B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN The current operation mode is maintained HEAT The unit enters the standby mode Operatio...

Page 8: ...rinse them in cool water Do not use detergent or hot water to avoid filter shrinking or deformation After cleaning dry them in the shade 3 Replacing the air filter Rear suction Hook the filter behind...

Page 9: ...the outlets of the indoor unit and the outdoor unit Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be leaking from the indo...

Page 10: ...r conditioner The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 30 seconds for system protection While the...

Page 11: ...may result in problems electric shock or fire Consult the dealer where you bought the air conditioner Do not attempt to repair or modify the air conditioner by yourself Incorrect work may result in el...

Page 12: ...3P472684 5A M16B252A 1707 HT The two dimensional bar code is a manufacturing code...

Page 13: ...OPERATION MANUAL WIRELESS REMOTE CONTROLLER KIT MODELS BRC086A11 BRC086A12...

Page 14: ...ns Be sure to establish an earth connection After reading keep this manual in a convenient place so that you can refer to it whenever necessary If the equipment is transferred to a new user be sure al...

Page 15: ...blockage may cause dripping resulting in fouling or failure of the object concerned After prolonged use check the unit stand and its mounts for damage If they are left in a damaged condition the unit...

Page 16: ...irflow rate setting Page 9 SUPER POWERFUL button SUPER POWERFUL operation Page 10 Explained by the HEAT PUMP model HEAT PUMP model BRC086A11 COOLING ONLY model BRC086A12 Display LCD Displays the curre...

Page 17: ...ge 12 ON TIMER button Page 13 CLOCK button Page 6 MODE selector button Selects the operation mode AUTO DRY COOL HEAT FAN Page 7 OFF TIMER button NIGHT SET mode Page 14 TIMER CANCEL button Cancels the...

Page 18: ...er holder to a wall 1 Choose a place from where the signals reach the unit 2 Attach the holder to a wall a pillar or similar location with the screws supplied with the holder 3 Place the remote contro...

Page 19: ...to the present time Holding down or rapidly increases or decreases the displayed time 5 Press Point the remote controller at the indoor unit when pressing the buttons blinks NOTE Note on setting the...

Page 20: ...mp lights green Display To stop operation Press again disappears from the LCD The OPERATION lamp goes off NOTE Notes on AUTO operation In AUTO operation the system selects an appropriate operation mod...

Page 21: ...ature setting at a moderate level helps save energy Recommended temperature setting For cooling 26 0 28 0 C For heating 20 0 24 0 C Cover windows with a blind or a curtain Blocking sunlight and air fr...

Page 22: ...quence AUTO Indoor unit quiet Air ow rate 1 5 Low to High When the airflow is set to quiet operation starts and noise from the indoor unit will become quieter In the quiet operation mode the airflow r...

Page 23: ...ll not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated In COOL HEAT and AUTO operation To maximise the cooling heatin...

Page 24: ...e LCD Not available in FAN mode To cancel operation Press again disappears from the LCD NOTE Notes on ECONO operation Pressing causes the settings to be cancelled and disappears from the LCD If the po...

Page 25: ...ped by using the remote controller or the indoor unit ON OFF switch when using OUTDOOR UNIT QUIET operation will remain displayed on the remote controller OUTDOOR UNIT QUIET operation will not reduce...

Page 26: ...tton increases or decreases the time setting by 10 minutes Holding down either button changes the setting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange D...

Page 27: ...setting rapidly 3 Press again and setting time are displayed on the LCD The TIMER lamp lights orange Display To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the...

Page 28: ...nd continue from STEP 2 of 24 HOUR ON OFF TIMER Page 13 14 Timer display mode cannot be changed while or are blinking Press or to stop the blinking Display Combining display modes Different display mo...

Page 29: ...SOR FAULT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR H8 DC CURRENT SENSOR FAULT H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR J6 FAULTY HEAT EXCHA...

Page 30: ...Memo 17...

Page 31: ...18...

Page 32: ...3P477582 2 M16B322 1706 HT The two dimensional bar code is a manufacturing code...

Reviews: