Note for Multi System

A multi system has one outdoor unit connected to multiple indoor units.

 

„

Selecting the operation mode

1. When the priority room setting is active but  

the set unit is not operating or when the priority 

room setting is inactive

When more than one indoor unit is operating, priority is given to the first 
unit that was turned on.
In this case, set the units that are turned on later to the same operation 
mode as the first unit.
Otherwise, they will enter the standby state.

2. 

With the priority room setting active

Refer to 

“Priority room setting” 

on the next page.

 

„

NIGHT QUIET mode (Available only for 

COOL operation)

NIGHT QUIET mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the night-time hours to prevent annoyance to neighbours.

• NIGHT QUIET mode is activated when the temperature drops 6°C or more below the highest temperature recorded that day.  

When the temperature difference between the current outdoor temperature and the maximum outdoor temperature becomes 
less than 4°C, this function will be cancelled.

• NIGHT QUIET mode slightly reduces the cooling efficiency of the unit.

 

„

OUTDOOR UNIT QUIET operation

For details on OUTDOOR UNIT QUIET operation, refer to the operation manual included with the remote controller.

1. 

When the priority room setting is active but the set unit is not operating or when the

 

priority room setting is inactive

When using the OUTDOOR UNIT QUIET operation feature with a multi system, set all indoor units to OUTDOOR UNIT QUIET 
operation using their remote controllers.
When cancelling OUTDOOR UNIT QUIET operation, simply cancel the mode on one of the operating indoor units using their 
remote controller.
However OUTDOOR UNIT QUIET operation will remain displayed on the remote controllers for the other rooms.
We recommend you cancel operation in all rooms using their remote controllers.

2. 

With the priority room setting active

Refer to 

“Priority room setting”

 on the next page.

Room A

Room B

Room C

Room D

Outdoor unit

NOTE

Notes on operation mode for a multi system

•  COOL, DRY and FAN operation may be used at the same time.

4

Multi Connection

Multi Connection

01_EN_3P620957-8A.indd   4

25-Aug-20   5:27:15 PM

Summary of Contents for CDKM25VVMG

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS CDKM25VVMG CDKM50VVMG CDKM60VVMG CDKM35VVMG 00_CV_3P620957 8A indd 1 31 Jul 20 1 59 56 PM...

Page 2: ...00_CV_3P620957 8A indd 2 31 Jul 20 1 59 56 PM...

Page 3: ...your physical condition and health Do not place objects including rods your fingers etc in the air inlet or outlet Product damage or personal injury may result due to contact with the air conditioner...

Page 4: ...er as this may result in electric shock or fire Do not place water containers vases etc above the unit as this may result in electric shock or fire hazards if they should topple over Do not insert the...

Page 5: ...around the unit Air outlet Air outlet grille field supply Air inlet Suction grille sold separately The suction grille is not included The appearance of the suction grille may differ between different...

Page 6: ...n the current outdoor temperature and the maximum outdoor temperature becomes less than 4 C this function will be cancelled NIGHT QUIET mode slightly reduces the cooling efficiency of the unit OUTDOOR...

Page 7: ...of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN The current operation mode is maintained 1 Priority when SUPER POWERFUL is used Example Room A is the priority room in...

Page 8: ...er Do not use detergent or hot water to avoid filter shrinking or deformation After cleaning dry them in the shade 3 Replacing the air filter Rear suction Hook the filter behind the flap situated at t...

Page 9: ...unit and the outdoor unit Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be leaking from the indoor unit Stop operation and...

Page 10: ...tion is stopped The outdoor fan continues rotating for another 30 seconds for system protection While the air conditioner is not in operation When the outdoor temperature is very high the outdoor fan...

Page 11: ...al sound is heard during operation The circuit breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burnin...

Page 12: ...M20N055 2008 HT The two dimensional bar code is a manufacturing code 3P620957 8A 00_CV_3P620957 8A indd 3 31 Jul 20 1 59 56 PM...

Reviews: