Daikin BRC1D619 Operation Manual Download Page 8

Operation manual

5

BRC1D

61

Remote controller

3P107422-3D

4. Description of the operation modes

1

FAN ONLY OPERATION 

In  this  mode,  air  only  circulates  without  heating  or
cooling. 

2

DRY OPERATION 

In  this  mode,  the  air  humidity  will  be  lowered  with  a
minimal temperature decrease.

The  temperature  and  fan  speed  are  controlled
automatically and cannot be controlled by the remote
controller. 

Dry operation will not function if the room temperature
is too low.

3

AUTOMATIC OPERATION 

In  this  mode,  the  controller  will  automatically  switch
between  heating  and  cooling  as  required  by  the
setpoint or limit temperature.

4

COOLING OPERATION 

In this mode, cooling will be activated as required by
the setpoint or limit temperature.

5

HEATING OPERATION 

In this mode, heating will be activated as required by
the setpoint or limit temperature.

Hot start (heat pump types only) 

At  the  start  of  a  heating  operation,  the  indoor  fan  is
stopped  until  a  certain  indoor  heat  exchanger
temperature is reached and 

 is displayed.

This prevents cold air from leaving the indoor unit.

Defrost (heat pump types only) 

In  heating  operation,  freezing  of  the  outdoor  heat
exchanger  may  occur.  If  so,  the  heating  capacity  of
the  system  lowers  and  the  system  goes  into  defrost
operation. The indoor unit fan stops and 

 is

displayed.  After  maximum  10  minutes  of  defrost
operation,  the  system  returns  to  heating  operation
again.

6

LIMIT OPERATION 

 & 

Limit operation is an additional mode that enables to
keep  the  room  temperature  within  certain  limits. The

  icons  are  displayed  to  confirm  the

activation of the limit operation.

7

LEAVE HOME 

LEAVE  HOME  is  a  feature  that  enables  to  keep  the
room  temperature  above  10°C  when  the  occupants
are  out.  This  function  will  switch  on  heating  if  the
installation is switched off. 

5.  Operation

Manual operation

In  manual  operation,  the  user  decides  about  the
settings  of  the  installation.  The  last  setting  remains
active until the user changes it.

As  the  controller  can  be  implemented  for  a  wide
variety of installations and features, it might occur that
you  select  a  function  that  is  not  available  on  your
installation;  if  this  is  the  case,  the 

  message

will appear.

Summary of Contents for BRC1D619

Page 1: ...R e m ote c ontrolle r B R C1D619 OPE R ATION MANUAL...

Page 2: ...1 1 1 2 9 3 25 22 11 10 37 35 27 26 12 14 17 34 24 5 20 21 18 16 13 15 19 32 31 30 29 28 4 36 33 8 23 7 6...

Page 3: ...2 Start 5s 5s 5s 5s 5s End...

Page 4: ...me adjustment air flow direction adjustment 2 CLOCK FUNCTION The clock functions are 24 hours real time clock day of the week indicator 3 SCHEDULE TIMER FUNCTION The schedule timer functions are a max...

Page 5: ...entilation icon appears when the ventilation is adjusted with the ventilation amount button only Simultaneously the ventilation amount is indicated by the fan speed icon see 22 6 AIR CLEANING ICON Thi...

Page 6: ...s only 20 AIR FLOW DIRECTION ICON This icon indicates the air flow direction only for installations with motorised air flow flaps 21 NOT AVAILABLE is displayed whenever a non installed option is addre...

Page 7: ...After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to operate the installation automatically setting the c...

Page 8: ...reached and is displayed This prevents cold air from leaving the indoor unit Defrost heat pump types only In heating operation freezing of the outdoor heat exchanger may occur If so the heating capac...

Page 9: ...TION User adjustable parameters Setpoint temperature use the buttons Fan speed use the button Air flow direction adjust use the button Ventilation mode use the button Ventilation amount use the button...

Page 10: ...he schedule timer Use the button to enable or disable the schedule timer To set up the SCHEDULE TIMER refer to chapter 6 Programming the schedule timer on page 10 KEEP IN MIND THAT THE BUTTON MUST BE...

Page 11: ...t will the schedule timer NOT do The schedule timer will not control fan speed control air flow direction control ventilation mode control ventilation amount change the operation mode for a scheduled...

Page 12: ...day not blinking you have now quit browsing How do I interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled it is important to...

Page 13: ...mming steps are limited to a minimum Below are some tips and tricks to ensure successful programming of the schedule timer familiarise yourself with the icons and the buttons you will need them when p...

Page 14: ...in limit operation the selected temperature will blink Enter the time when the action must start using the buttons min step 10 minutes NOTE When changing day during programming you will have to confir...

Page 15: ...d if no actions were copied from Monday to Tuesday 2 I WANT TO EDIT PROGRAMMED ACTIONS Editing programmed actions is easy Make sure you are not in program mode not blinking if required press the butto...

Page 16: ...p to solve your problem If you cannot remedy the problem consult your installer No readings on the remote controller display blank Check if the mains power is still applied to your installation Only i...

Page 17: ......

Page 18: ......

Page 19: ...EM04A046 0501 3P107422 3D...

Reviews: