• Outdoor Unit • AZQS-BV1
2
• Split - Sky Air • AZQS-BV1
6
2
Specifications
Notes
(1) See separate drawings for electrical data
(2) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents
produced by equipment connected to public low-voltage systems with input current \>16A and
≤
75A per phase
(3) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
(4) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A
and
≤
75A per phase.
(5) Short-circuit power
(6) RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
(7) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
Piping connections
Liquid
Quantity
1
Type
Flare connection
OD
mm
9.52
Gas
Quantity
1
Type
Flare connection
OD
mm
15.9
Drain
Quantity
3
5
Type
Hole
ID
mm
-
OD
mm
26
Piping length
OU - IU Min.
m
5
Max.
m
30
50
System Equival
ent
m
40
70
Chargel
ess
m
30
Additional refrigerant charge
kg/m
See installation manual
Level difference
IU - OU Max.
m
15.0
30.0
IU - IU
Max.
m
-
0.5
Heat insulation
Both liquid and gas pipes
Defrost method
Pressure equalising
Reversed cycle
Defrost control
Sensor for outdoor heat exchanger temperature
Safety devices
Item
01
High pressure switch
02
Fan motor thermal protection
03
Fuse
2-6 Electrical Specifications
AZQS71BV1
AZQS100BV1
AZQS125BV1
AZQS140BV1
Power supply
Name
V1
Phase
1~
Frequency
Hz
50
Voltage
V
220-240
Voltage range
Min.
%
-10
Max.
%
10
Current
Nominal running
current (RLA)
Cooling
A
16.20
-
Zmax
List
Complies to EN6100-3-
3
Complies to EN61000-3-12
Recommended fuses
A
20
32
Current - 50Hz
Maximum fuse amps (MFA)
A
20
-
Current - 60Hz
Maximum fuse amps (MFA)
A
-
Wiring connections
For power supply
Remark
-
See installation manual outdoor unit
For connection with
indoor
Remark
-
See installation manual outdoor unit
Power supply intake
Outdoor unit only
2-5 Technical Specifications
AZQS71BV1
AZQS100BV1
AZQS125BV1
AZQS140BV1
Summary of Contents for AZQS-BV1
Page 1: ...Air Conditioning Technical Data EEDEN14 131 AZQS BV1...
Page 2: ......
Page 9: ...3 3 Split Sky Air AZQS BV1 7 Outdoor Unit AZQS BV1 3 Electrical data 3 1 Electrical Data...
Page 10: ...Outdoor Unit AZQS BV1 4 Split Sky Air AZQS BV1 8 4 Options 4 1 Options...
Page 11: ...3 5 Split Sky Air AZQS BV1 9 Outdoor Unit AZQS BV1 5 Combination table 5 1 Combination Table...
Page 23: ...3 8 Split Sky Air AZQS BV1 21 Outdoor Unit AZQS BV1 8 Centre of gravity 8 1 Centre of Gravity...
Page 24: ...Outdoor Unit AZQS BV1 8 Split Sky Air AZQS BV1 22 8 Centre of gravity 8 1 Centre of Gravity...
Page 25: ...3 9 Split Sky Air AZQS BV1 23 Outdoor Unit AZQS BV1 9 Piping diagrams 9 1 Piping Diagrams...
Page 28: ...Outdoor Unit AZQS BV1 11 Split Sky Air AZQS BV1 26 11 Sound data 11 1 Sound Power Spectrum...
Page 32: ...Outdoor Unit AZQS BV1 12 Split Sky Air AZQS BV1 30 12 Installation 12 1 Installation Method...
Page 33: ...3 12 Split Sky Air AZQS BV1 31 Outdoor Unit AZQS BV1 12 Installation 12 1 Installation Method...