10
|
Configuration
Installer reference guide
42
35AMV1B35AMV1B
Daikin room air conditioner
4P513661-10K – 2021.07
10 Configuration
10.1 To set a different address
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1
Remove the batteries from the user interface.
2
Cut the address jumper.
a
a
a
Address jumper
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3
Turn the power supply on.
Result:
The flap of the indoor unit will open and close to set the reference position.
INFORMATION
▪
The following setting MUST be completed within 5 minutes after the power
supply is turned on.
▪
In case you could NOT complete the setting in time, turn the power supply off
and wait at least 1 minute before turning the power supply back on.
4
Press simultaneously
,
and
.
5
Press
and select .
6
Press
.
a
b
a
Operation lamp
b
Indoor unit ON/OFF switch
7
Press the indoor unit ON/OFF switch while the operation lamp is blinking.
Jumper
Address
Factory setting
1
After cutting with nippers
2