![background image](http://html.mh-extra.com/html/daikin/atxf50a2v1b/atxf50a2v1b_installers-reference-manual_501392042.webp)
10
|
Configuration
Installer reference guide
42
FTXP-M + FTXF-D + FTXF-A + ATXF-A
Daikin room air conditioner
4P513661-12L – 2021.07
10 Configuration
10.1 To set a different address
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1
Remove the batteries from the user interface.
2
Cut the address jumper.
a
a
a
Address jumper
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3
Turn the power supply on.
Result:
The flap of the indoor unit will open and close to set the reference position.
INFORMATION
▪
For FTXF and ATXF units, the following setting MUST be completed within
5 minutes after the power supply is turned on.
▪
In case you could NOT complete the setting in time, turn the power supply off
and wait at least 1 minute before turning the power supply back on.
4
Press simultaneously:
Model
Buttons
FTXP
,
and
FTXF, ATXF
,
and
5
Press:
Model
Button
FTXP
FTXF, ATXF
6
Select:
Model
Symbol
FTXP
FTXF, ATXF
7
Press:
Summary of Contents for ATXF50A2V1B