1-6
Condensed Water Disposal Of Outdoor Unit
(Heat Pump Unit Only)
There are 2 holes on the base of Outdoor Unit for condensed
water to flow out. Insert the drain elbow to one of the
holes.
To install the drain elbow, first insert one portion of the
hook to the base (portion A), then pull the drain elbow in
the direction shown by the arrow while inserting the other
portion to the base. After installation, check to ensure that
the drain elbow clings to base firmly.
If the unit is installed in a snowy and chilly area, condensed
water may freeze in the base. In such case, please remove
plug at the bottom of unit to smooth the drainage.
•
•
•
Please remove side
plate when connecting
the piping and
connecting cord
PUSH & PULL UP
BASE
A
DRAIN ELBOW
DRAIN ELBOW
PLUG
The indoor unit must be installed in such a way so as to prevent
short circuit of the cool discharged air with the hot return air.
Please follow the installation clearance shown in the figure. Do
not place the indoor unit where there could be direct sunlight
shining on it. Also, this location must be suitable for piping
and drainage, and be away from doors or windows.
min. 50
(Space for
maintenance)
Air flow
(Indoor)
The refrigerant piping can be routed to the unit in a number of
ways (left or right from the back of the unit), by using the cut-
out holes on the casing of the unit (see figure). Bend the pipes
carefully to the required position in order to align it with the
holes. For the side and bottom, hold the bottom of the piping
and then position it to the required direction (see figure). The
condensation drain hose can be taped to the pipes.
Right-side, right-back or right-bottom piping
min. 50
(Space for
maintenance)
min. 75
(Space for
performance)
Required space
Right-back piping
All dimensions are in mm
Right-bottom
piping
Right-side piping
Remove pipe port cover
here for right-side piping
Left-back piping
Left-side piping
Left-bottom piping
Left-side, left-back or left-bottom piping
INSTALLATION OF THE INDOOR UNIT
Remove pipe port cover
here for right-bottom piping
Bind coolant pipe
and drain hose
together with
insulating tape.
Remove pipe port
cover here for
left-side piping
Remove pipe port cover
here for left-bottom piping
Summary of Contents for ATXB50CV1B
Page 2: ......
Page 85: ...6 3 H MAH E CTOPO HO 1 1 OFF PE PE EH E...
Page 86: ...6 4 R410A 1 2087 5 1 1 2 1 2 2 2 1 2 3 4 5 6...
Page 88: ...6 6 A 2 A 50 50 75 c y ox...
Page 96: ...6 14 FRONT K a B 2 1 4 2 5 4 3 K a CTOPO HO 1 3 2 4...
Page 97: ...10 6 15 2 1 2 c 3 40 104 F 1 2 3 1 2 40 104 F 1 2 1 2 CTOPO HO...
Page 98: ...6 16 3 1 3 4 2 3 4 5 6 2 30 C 86 F CTOPO HO 40 C...
Page 119: ...3 1 4 3 2 3 4 5 6 86 F 30 C 40...
Page 120: ...1 2 2 3 1 40 2 3 1 40 2 10...
Page 121: ...FRONT 3 1 4 2 1 2 4 2 5 1 3 1 3...
Page 128: ...190 173 61 310 61 48 45 580 1065 219 40 40 91 45 65 7 ATXB50 60CV1B 65 2000 65 7...
Page 129: ...A A 75 50 50...
Page 130: ...75 50 M4 x 12L 1 2 3 500 2 D C B A 500 300 1000 300 C D A B H H 2...
Page 131: ...R410A 2087 5 GWP 1 GWP 1 1 2 2 1 1 2 2 3 4 5 6 1 2...
Page 132: ...OFF 1 1 ON OFF OFF...
Page 135: ......