![Daikin ATX20JV1B Service Manual Download Page 21](http://html.mh-extra.com/html/daikin/atx20jv1b/atx20jv1b_service-manual_501375021.webp)
Si041051
Removal of Swing Motor / PCBs
Removal Procedure
19
4. Remove the control PCB.
1
Lift the shield plate (1)
and unfasten the 2
hooks.
2
Slide the shield plate
(1) and remove it.
3
Release the harnesses
from the hooks.
4
Disconnect the
terminals from the
terminal board with
pliers.
Step
Procedure
Points
(R12061)
Hook
Shield plate (1)
(R12062)
(R14609)