background image

3

2

• Split - Sky Air • ATX-JV

3

• Indoor Unit • ATX-JV

2

Specifications

2-1 Technical Specifications

ATX20JV

ATX25JV

ATX35JV

Power input

Cooling

Nom.

kW

0.040

Heating

Nom.

kW

0.040

Casing

Colour

White

Dimensions

Unit

Height/Width/
Depth

mm

283/770/198

Packed unit

Height/Width/
Depth

mm

345/846/266

Weight

Unit

kg

7

Packed unit

kg

11

Heat exchanger

Length

mm

610

Rows

Quantity

2

Fin pitch

mm

1.4

Stages

Quantity

14

Tube type

ø7 Hi-XA

Fin

Type

ML fin (Multi louver)

Fan

Type

Cross flow fan

Air flow rate

Cooling High

m³/min

9.1

9.2

9.3

cfm

321

325

328

Nom.

m³/min

7.4

7.6

7.7

cfm

261

268

272

Low

m³/min

5.9

6.0

6.1

cfm

208

212

215

Silent 
operati
on

m³/min

4.7

4.8

4.9

cfm

166

169

173

Heating High

m³/min

9.4

9.7

10.1

cfm

331

342

356

Nom.

m³/min

7.8

8.0

8.4

cfm

276

283

295

Low

m³/min

6.3

6.7

cfm

222

235

Silent 
operati
on

m³/min

5.5

5.7

cfm

194

201

Fan motor

Model

MM6C02J2VA

Speed

Steps

5 + silent, + auto

Cooling High/

Mediu
m/Low/
Silent 
operati
on

rpm

1,210/990/780/630

1,250/1,030/820/630

1,300/1,070/850/680

Heating High/

Mediu
m/Low/
Silent 
operati
on

rpm

1,260/1,090/920/820

1,300/1,110/920/820

1,340/1,150/960/850

Output

High

W

16

Sound power level

Cooling

dBA

55

58

Heating

dBA

55

58

Sound pressure level

Cooling

High/Nom./Low/
Silent operation

dBA

39/33/25/22

40/33/26/22

41/34/27/23

Heating

Super high/High/
Nom./Low/Silent 
operation

dBA

-/39/34/28/25

-/40/34/28/25

-/41/35/29/26

Refrigerant

Type

R-410A

Piping connections

Liquid

OD

6.35

Gas

OD

9.5

Drain

18

Heat insulation

Both liquid and gas pipes

Summary of Contents for ATX20JV

Page 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN14 030 ATX JV ...

Page 2: ......

Page 3: ...ENTS ATX JV 1 Features 2 2 Specifications 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawings 5 4 Centre of gravity 6 5 Piping diagrams 7 6 Wiring diagrams 8 Wiring Diagrams Single Phase 8 7 Sound data 9 Sound Pressure Spectrum 9 ...

Page 4: ...the preset mode Indoor unit silent operation silent button on the remote control lowers the operation sound of the indoor unit by 3dBA Titanium apatite photocatalytic air purification filter removes airborne microscopic particles powerfully decomposes odours and helps to prevent the propagation of bacteria viruses microbes to ensure a steady supply of clean air Vertical auto swing moves the discha...

Page 5: ...in 4 7 4 8 4 9 cfm 166 169 173 Heating High m min 9 4 9 7 10 1 cfm 331 342 356 Nom m min 7 8 8 0 8 4 cfm 276 283 295 Low m min 6 3 6 7 cfm 222 235 Silent operati on m min 5 5 5 7 cfm 194 201 Fan motor Model MM6C02J2VA Speed Steps 5 silent auto Cooling High Mediu m Low Silent operati on rpm 1 210 990 780 630 1 250 1 030 820 630 1 300 1 070 850 680 Heating High Mediu m Low Silent operati on rpm 1 26...

Page 6: ...ity 1 Standard Accessories Installation manual Quantity 1 Standard Accessories Infrared remote control Standard Accessories Titanium apatite photocatalytic air purification filter without frame Notes 1 SL The silent fan level of the air flow rate setting Temperature control Microcomputer control Air direction control Right Left Horizontal Downward Air filter Type Removable washable mildew proof 2 ...

Page 7: ...3 3 Split Sky Air ATX JV 5 Indoor Unit ATX JV 3 Dimensional drawings 3 1 Dimensional Drawings ...

Page 8: ... Indoor Unit ATX JV 4 Split Sky Air ATX JV 6 4 Centre of gravity 4 1 Centre of Gravity ...

Page 9: ...3 5 Split Sky Air ATX JV 7 Indoor Unit ATX JV 5 Piping diagrams 5 1 Piping Diagrams ...

Page 10: ... Indoor Unit ATX JV 6 Split Sky Air ATX JV 8 6 Wiring diagrams 6 1 Wiring Diagrams Single Phase ...

Page 11: ...3 7 Split Sky Air ATX JV 9 Indoor Unit ATX JV 7 Sound data 7 1 Sound Pressure Spectrum ...

Page 12: ... Indoor Unit ATX JV 7 Split Sky Air ATX JV 10 7 Sound data 7 1 Sound Pressure Spectrum ...

Page 13: ...compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose of its content and the products and services presented therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broa...