![background image](http://html.mh-extra.com/html/daikin/atkc09rv2s/atkc09rv2s_service-manual_501362012.webp)
Swing Motor / PCBs
Si041264EC
10
Removal Procedure
3. Remove the display/
signal receiver PCB.
1
Unfasten the hook and
release the display/
signal receiver PCB
ASSY.
2
3
Turn over the display/
signal receiver PCB
ASSY.
Unfasten the 3 hooks
and remove the display/
signal receiver PCB.
4
Disconnect the
connector [S27].
[S27]: control PCB
4. Remove the control PCB.
1
2
Lift the shield plate (2)
and unfasten the 2
hooks.
Slide the shield plate
(2) and remove it.
Step
Procedure
Points
(R23307)
Hook
Display/signal receiver PCB ASSY
(R23308)
Hook
Display/
signal
receiver
PCB
(R22350)
[S27]
TIMER lamp
Signal receiver
Operation lamp
ON/OFF button
(Forced cooling operation
ON/OFF button)
(R23309)
Hook
Shield plate (2)