Removal of Electrical Box / PCBs
Si00-874
10
Removal Procedure
9
Lift and remove the
electrical box.
3. Remove the main PCB.
1: black, upper
2: white, lower
3: red, upper
(
) : green / yellow, lower
1
Remove the screw on
the terminal board.
2
Cut the clamp.
3
Remove the 2 screws
of the earth / ground
wires.
4
Disconnect the 2
terminals of the reactor.
Step
Procedure
Points
(R11236)
Electrical box
(R18222)
Terminal board
Clamp
Main PCB
(R15867)
(R18751)
Reactor
Brown