![background image](http://html.mh-extra.com/html/daikin/arkh20cavmb/arkh20cavmb_service-manual_501298211.webp)
Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
SiENBE04-401A
202
Removal Procedure
Step
Procedure
Points
3
Remove the fan motor
assembly.
4
The propeller fan can
be removed when the
washer faced nut (M8)
is removed.
When restoring, match the
t
mark of the propeller fan with
the D-cut of the motor shaft.
The fan should be restored
so that the mark
z
will be at
upper part of the fan motor.
5
Release the lead wire
from the hooks.
(R4050)
Propeller
fan
(R4051)
Mark
(R4052)