9
|
Electrical installation
Installer reference guide
105
EPRA14~W1 + ETV23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
9.2 Connections to the outdoor unit
Item
Description
Power supply cable
See
"9.2.1 To connect the electrical wiring to the
Interconnection cable
Drain tube heater cable
Connection for power
saving function (only for V3
models)
Air thermistor cable
See
"9.2.2 To reposition the air thermistor on the
9.2.1 To connect the electrical wiring to the outdoor unit
1
Open the switch box cover. See
"7.2.2 To open the outdoor unit"
68].
2
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
3
Insert the cables at the back of the unit, and route them through the factory-
mounted cable sleeves into the switch box.
d
c2
b2
c1
b1
a1
a2
a1+a2
Power supply cable (field supply)
b1+b2
Interconnection cable (field supply)
c1+c2
(optional) Drain tube heater cable (field supply)
d
Cable sleeves (factory-mounted)
4
Inside the switch box, connect the wires to the appropriate terminals, and fix
the cables with cable ties. See:
Summary of Contents for Altherma F