Once you have the valve body installed, turn the red plate on the valve body so that the
indicators 0 – 10 are between the sanitary hot water and the space heating loads.
Install the white plastic blocking pointer to the shaft and turn to mid position which is
number 5 as shown in the picture.
Then fit the motor holding pin at position 5 if installed this way.
After this fit the motor to the valve body and secure with the centre pin.
Altherma ESBE 3 Port Valve – UKEIOE3PV.05.09
Page 5
Finally set the jumper pins as shown on the
previous page, when the motor is powered
up for the first time you need to ensure that
you change the jumper pins so that the white
blocking pointer motors towards the sanitary
hot water.
Once the wiring is correct turn the power on.