EKRTCTRL1

EKRTCTRL2

EKWHCTRL0

EKWHCTRL1

EKPCBO

USER MANUAL

Daikin Altherma

heat pump convector options

Summary of Contents for Altherma EKRTCTRL1

Page 1: ...EKRTCTRL1 EKRTCTRL2 EKWHCTRL0 EKWHCTRL1 EKPCBO USER MANUAL Daikin Altherma heat pump convector options ...

Page 2: ...e use of the appliance in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information for the installer S Service Refers to pages containing instructions or information for the CUSTOMER TECHNICAL ASSISTANCE SERVICE installer Editorial pictograms Safety pictograms Warning The operation...

Page 3: ... 8 2 15 Deactivation 9 2 16 Room temperature probe regulation offset 9 2 17 Switching off for long periods 9 2 18 Error signals 9 3 EKWHCTRL1 3 1 Wall mounted SMART TOUCH electronic control panel with room probe 10 3 2 Display 10 3 3 Key function 10 3 4 General On Switch 11 3 5 Activation 11 3 6 Heating cooling operation modes setting 11 3 7 Stand By 11 3 8 Temperature selection 11 3 9 Automatic o...

Page 4: ...13 Room temperature probe regulation offset 17 4 14 Switching off for long periods 17 4 15 Error signals 17 5 EKPCBO 5 1 On board speed selector for connecting to standard thermostat 18 5 2 LED indications 18 5 3 General On Switch 18 5 4 Activation 19 5 5 Stand By 19 5 6 Ventilation speed regulation 19 5 7 Deactivation 19 5 8 Switching off for long periods 19 5 9 Error status warnings 19 6 MAINTEN...

Page 5: ...product that uses electricity and water such as The unit can be used by children over the age of 8 and by people with reduced physical sensory or mental capabilities or with no experience or necessary knowledge as long as they are monitored or after they have received instructions on the safe use of the unit and have understood the dangers involved Children must not play with the appliance The cle...

Page 6: ...ous functions are set using 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL1 Automatic operation Silent operation Maximum ventilation speed Night time operation Heating on Cooling on Supervision on Flashing with presence switch CP closed Alarm indicator solid light Panel off indicator Resistance active indicator Temp is for increasing the s...

Page 7: ...these values for brief periods and then set a intermediate value The controller is very precise set it to the required value and wait for the controller to regulate itself according to the actual room temperature detected To activate the device Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heating and cooling which is indicated by the 2 ...

Page 8: ... whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press and hold the Max Operation key The function being activated is indicated by the relevant symbol appearing on the display Key Operation Display Press and hold the Night time operation key The function being activated is indicated by the relevant symbol appearing on the display Key Operati...

Page 9: ...tment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0 1 K intervals After 20 seconds from the last action the panel switches off and the setting is stored The controller also ensures anti freezing when in stand by Key Operation Display Press and hold the ON Stand By key for approx 2 seconds No illuminated signals on the display at all means that the system is in stand by n...

Page 10: ...e also shown on the display by using 8 specific symbols Automatic operation Silent operation Maximum ventilation speed Night time operation Heating on Cooling on Supervision on Flashing with presence switch CP closed Alarm indicator solid light Panel off indicator Resistance active indicator The various functions are set using 8 backlit keys Temp is for increasing the set temperature Temp is for d...

Page 11: ... To activate the device Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heating and cooling which is indicated by the 2 symbols that appear if heating or cooling is active When heating the symbol displays when the set point is higher than ambient temperature both are off when the set point is lower When cooling the symbol displays when the...

Page 12: ...this is indicated by bL appearing on the display All actions are disabled to the user and whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press and hold the Max Operation key The function being activated is indicated by the relevant symbol appearing on the display Key Operation Display Press and hold the Night time operation key The function...

Page 13: ...evice Key Operation Display With the display off press and hold the key for 5 seconds to access the menu which allows adjustment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0 1 K intervals After 20 seconds from the last action the panel switches off and the setting is stored Error Display Room temperature probe fault on the thermostat Fault or connection of a double remo...

Page 14: ...ing 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL2 Automatic operation in steps Minimum operation Maximum ventilation speed Super silent operation Heating on Cooling on Supervision active flashing light Alarm indicator solid light Panel off indicator Resistance active indicator Temp is for increasing the set temperature by 1 K Temp is for...

Page 15: ...opened The adjustment range is from 16 to 28 C in intervals of 1 C but out of range values are also accepted from 5 C to 40 C unless in auto mode Only set these values for brief periods and then set a intermediate value To activate the device Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heating and cooling which is indicated by the 2 sy...

Page 16: ...ivated immediately whether heating or cooling Once the desired room temperature is reached we recommend selecting one of the other 3 operation modes for increased comfort and sound levels In minimum mode the number of fan revolutions is limited both when heating and cooling Key Operation Display By pressing both the and keys for 3 seconds all keys are locked locally and this is indicated by bL app...

Page 17: ...ustment with care and only after having actually detected a discrepancy compared with the actual room temperature using a reliable device Key Operation Display With the display off press and hold the key for 5 seconds to access the menu which allows adjustment using the and keys of the AIR probe offset displayed from 9 to 12 K in 1 K intervals After 20 seconds from the last action the panel switch...

Page 18: ... series After 20 seconds from the last action the LED brightness will be reduced for improved night time comfort Press any key to restore maximum brightness The 5 LEDs display the operational states Minimum speed selected Medium speed selected Maximum speed selected Supersilent function selected Fan coil off or TA contact open flashing Warning Led speed selection key EKPCBO General On Switch To ma...

Page 19: ...ey Operation Display Each time the mode off button is pressed the fan speed moves between supersilent minimum medium and maximum The function being activated is indicated by the relevant symbol appearing on the display Deactivation Switching off for long periods When switching off for a season or for holidays proceed as follows Deactivate the device Turn the general unit switch to off Key Operatio...

Page 20: ...he painted surfaces When necessary clean the outer surfaces of the heat pump convector with a soft damp cloth Cleaning air suction filter To remove the grill lift the grill until it is completely released from the seat lit the grill and slide it outwards then remove the filter by pulling it outwards Extraction of filter cells After a period of continuous operation and in consideration of the conce...

Page 21: ...ng detergents or solvents and leave to dry It is forbidden to use the unit without the net filters The appliance is fitted with a safety switch that prevents the operation of the cooler with the mobile panel missing or out of position After finishing the cleaning of the filter check that the panel is mounted correctly Cleaning filtering seats ...

Page 22: ...gs into the special slots turn it and hook it up with a slight tap on the upper part Ending Cleaning Operations Energy saving tips Always keep the filters clean when far possible keep the doors and windows closed in the room being conditioned limit where possible the effect of direct sun rays in the rooms being conditioned use curtains shutters etc ...

Page 23: ...fan can turn freely The microswitch that stops ventilation when opening the filter grill doesn t close properly Check that closing the grill closes the contact on the microswitch Electrical connections are incorrect Check the electrical connections The device leaks water when heating Water leakage from the system plumbing Check for leaks and tighten all connections Leaks from the valve group Check...

Page 24: ...Copyright 2019 Daikin ...