background image

5 Energy visualisation

Operation manual

10

EJHA04AAV3

Daikin Altherma hybrid monobloc – Heat pump module

4P531174-1B – 2018.10

3

Press 

 to save the schedule.

INFORMATION

The values for High, Medium and Low correspond with the
electricity  price  values  for  High,  Medium  and  Low
previously set. If no schedule is set, the electricity price for
High is taken into account.

4.4

About energy prices in case of an
incentive per kWh renewable
energy

An  incentive  can  be  taken  into  account  when  setting  the  energy
prices.  Although  the  running  cost  can  increase,  the  total  operation
cost, taking into account the reimbursement will be optimized.

NOTICE

Make sure to modify the setting of the energy prices at the
end of the incentive period.

4.4.1

To set the gas price in case of an
incentive per kWh renewable energy

Prerequisite: 

Calculate  the  value  for  the  gas  price  with  following

formula: actual gas price+(incentive/kWh×0.9)

1

Go to [7.4.6]: 

 > User settings > Preset values > Fuel price.

2

Use 

 and 

 to set the correct price.

3

Press 

 to confirm.

4.4.2

To set the electricity price in case of an
incentive per kWh renewable energy

Prerequisite: 

Calculate  the  value  for  the  electricity  price  with

following formula: actual electricity price+incentive/kWh.

1

Go to [7.4.5]: 

 > User settings > Preset values > Elec price.

2

Use 

 and 

 to set the correct prices for High, Medium and

Low, according to your electricity tariff.

3

Press 

 to confirm.

4.4.3

Example

This  is  an  example  and  the  prices  and/or  values  used  in  this
example are NOT accurate.

Data

Pence/kWh

Gas price

4.08

Electricity price

12.49

Renewable heat incentive per
kWh

5

Calculation of the gas price:

Gas price=Actual gas price+(incentive/kWh×0.9)

Gas price=4.08+(5×0.9)

Gas price=8.58

Calculation of the electricity price:

Electricity price=Actual electricity price+incentive/kWh

Electricity price=12.49+5

Electricity price=17.49

Price

Value in breadcrumb

Gas: 4.08 pence/kWh

[7.4.6]=8.58

Electricity: 12.49 pence/kWh

[7.4.5]=17.49

5

Energy visualisation

The user interface is able to graphically display energy statistics for:

▪ consumed electricity: calculated by the interface itself based on an

internal calculation.

▪ consumed  gas  (only  in  case  of  *HY32AA  gas  boiler):

calculated by the interface itself based on an internal calculation.

5.1

To view the energy statistics

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [6.2]: 

 > Information > Energy metering.

2

Select Consumed elec. or Consumed gas.

3

Use  the 

  and 

  buttons  to  toggle  between  views  of  the

current  month,  the  previous  month,  the  last  12  months  and  a
general overview.

4

Use  the 

  and 

  buttons  to  toggle  between  different  modes

(if applicable).

6

Energy saving tips

Tips about room temperature

▪ Make sure the desired room temperature is NEVER too high, but

ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If

necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature. 

Example: 

When  you  have  a  party,  or  when  you

are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode. 

Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage

comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

Summary of Contents for altherma EJHA04AAV3

Page 1: ...Operation manual Daikin Altherma hybrid monobloc Heat pump module English Operation manual Daikin Altherma hybrid monobloc Heat pump module EJHA04AAV3...

Page 2: ...om The system is making gurgling noises after commissioning 12 9 Disposal 12 10 Glossary 12 1 About this document Thank you for purchasing this product Please Read the documentation carefully before o...

Page 3: ...omestic hot water tank a b c e f d B C A Gas boiler third party instant domestic hot water not for Switzerland a b c e f d B C A A Living room B Bedroom C Technical room Example Garage a Outdoor unit...

Page 4: ...ce operation mode Heating Not available Icon Description Heat pump compressor operation or boiler operation This symbol is related to the home page Desired room temperature preset value Comfort daytim...

Page 5: ...oom temperature follows the manually adjusted value but will return to the scheduled value after the overrule period Temperature lock 2 4 6 8 hours or permanent To set the overrule period Prerequisite...

Page 6: ...Detailed 15 20 60 C Storage comfort Tank Mon 15 20 60 C 00 00 Mon Tue Tank Storage comfort To read out and adjust the desired reheat temperature in scheduled and reheat mode 1 Go to 7 4 3 3 User sett...

Page 7: ...or Monday Use and to select an entry Use and to change the value of an entry To copy from one day to another 1 Select the day from which you want to copy and press Example Monday 2 Select Copy day and...

Page 8: ...information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of meas...

Page 9: ...ontact helpdesk number 4 Setting the energy prices If your system s savings mode is set to Economical it allows you to set a fixed gas price 3 electricity price levels a weekly schedule timer for elec...

Page 10: ...ace itself based on an internal calculation consumed gas only in case of HY2KOMB28 32AA gas boiler calculated by the interface itself based on an internal calculation 5 1 To view the energy statistics...

Page 11: ...rce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside th...

Page 12: ...s will appear on the user interface Possible cause Corrective action Heat pump is damaged Press to view a description of the problem Press again Select to allow the gas boiler to take over the entire...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P531174 1B 2018 10 Copyright 2018 Daikin...

Reviews: