background image

4 Operation

User reference guide

7

EHVZ04~16S18CB
Daikin Altherma – Low temperature split
4P401674-1 – 2015.02

"4.7 Preset values and schedules" on page 16

Leaving water temperature of the main zone

To control the leaving water temperature of the main zone, you can
do the following:

You can…

Location

Read out 

the desired leaving water

temperature

.

Leaving water
temperature home
page (main)

Adjust 

the leaving water 

temperature

.

Condition: Leaving water set point is NOT
linked with the room temperature set point.

Only change this if the desired room
temperature cannot be reached.

Define preset values.

Condition: Leaving water set point is linked
with the room temperature set point.

Only change this if the desired room
temperature cannot be reached.

Menu structure

See also:

"4.4.6  Room  thermostat  control  -  Using  the  leaving  water
temperature home pages" on page 8

"4.7 Preset values and schedules" on page 16

4.4.5

Room thermostat control - Using the
room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to

"4.6.6 Configuring user profile and home pages" on page 15

.

User profile = Basic

User profile = Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room
temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature
schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset
value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

Example: Temporarily overruling the schedule
AND changing the mode to preset value

You have configured the following settings:

Settings

Description

Preset values

Comfort (heating) =
20°C

Desired temperature when
you are at home.

Eco (heating) = 18°C Desired temperature:

▪ When you are away

▪ During the night

Schedule

07:00 Comfort

You are at home.

Desired temperature =
preset value (Comfort
(heating)).

09:00 Eco

You are away.

Desired temperature =
preset value (Eco
(heating)).

17:00 Comfort

You are at home.

Desired temperature =
preset value (Comfort
(heating)).

19:00 21°C

You are at home and want
it to be a little warmer.

Desired temperature =
custom temperature.

23:00 Eco

Desired temperature =
preset value (Eco
(heating)).

Overrule period
(Temperature
lock)

2 hours

If you temporarily overrule
the schedule by a preset
value, after 2 hours the
schedule will be used
again.

If user profile = Basic, then you can 

temporarily overrule

 the room

temperature schedule by pressing 

 or 

.

Situation

Description

15:20

18.0°C

15:20

19.0°C

15:20 => Scheduled temperature
= preset value (Eco (heating)) =
18°C.

You 

temporarily overrule

 the

schedule.

Desired temperature = custom
temperature = 19°C.

At the next scheduled action
(17:00), the schedule will be
used again.

If user profile = Detailed, then you can:

Temporarily  overrule

  the  room  temperature  schedule  by

pressing 

 or 

 (same as if user profile = Basic)

Summary of Contents for Altherma EHVZ08S18CB

Page 1: ...User reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHVZ04S18CB EHVZ08S18CB EHVZ16S18CB...

Page 2: ...ctions 15 4 7 Preset values and schedules 16 4 7 1 Using preset values 16 4 7 2 Using and programming schedules 16 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water...

Page 3: ...for reuse By ensuring waste batteries are disposed of correctly you will help to prevent potential negative consequences for the environment and human health 2 About this document Thank you for purch...

Page 4: ...taller settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu...

Page 5: ...water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is displayed 2 Press again to display the next home page if any 4 3 2 Using the menu struc...

Page 6: ...emperature 2 Check the following If Then the temperature control is Main zone Additional zone if any Room temperature is listed under 6 1 Information Sensor information Room thermostat control Go to n...

Page 7: ...d temperature 22 0 C Desired temperature To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temperature To change the mode from sc...

Page 8: ...mfort will be used until 02 00 After that the schedule will be used again Usage example You go away for a couple of hours If you are in the following situation You are using the following room tempera...

Page 9: ...ess or to adjust overrule To adjust the leaving water temperature additional 1 Go to the additional leaving water temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In ca...

Page 10: ...temperature home page LWT add 2 Press or to adjust Example 45 C 47 C INFORMATION In case of weather dependency an offset value can be modified 4 5 Domestic hot water control 4 5 1 About domestic hot w...

Page 11: ...in and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats In scheduled mode you can do the following You can Location Read out the active or next scheduled desired temper...

Page 12: ...ode About the DHW tank booster mode You can use the DHW tank booster mode to immediately start heating up the water to the preset value Storage comfort However this consumes extra energy To check if t...

Page 13: ...F to ensure the heating capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following Prerequisite You switched the permission leve...

Page 14: ...lect No and press Usage example You go away during the winter If you are in the following situation In 2 days you go away for 2 weeks during the winter You want to save energy but prevent your house f...

Page 15: ...30 Actual temperature Room Scheduled Mon Tue To configure which home pages are made available to the end user Prerequisite You switched the permission level to Advanced end user 1 Go to 7 1 4 User set...

Page 16: ...alue Eco preset value Custom temperature Main leaving water temperature Additional leaving water temperature Program when the additional leaving water temperature is turned ON and OFF Control Possible...

Page 17: ...and press 2 Select User defined 1 User defined 2 or User defined 3 and press 3 Change the name and press Only applicable for room temperature schedules Example MyWeekSchedule To select which schedule...

Page 18: ...Set weather dependent 2 For main leaving water temperature zone 7 7 1 modify with and confirm with 3 If applicable for additional leaving water temperature zone 7 7 2 modify with and confirm with Set...

Page 19: ...Error handling User permission level Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User...

Page 20: ...the DHW tank booster mode is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating in...

Page 21: ...eck the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 7 4 Symptom You are feeling too cold hot in your living r...

Page 22: ...et of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operat...

Page 23: ......

Page 24: ...4P401674 1 2015 02 Copyright 2015 Daikin...

Reviews: