background image

3 Operation

Operation manual

4

08S18+23DA

Daikin Altherma – Low temperature split

4P495247-1C – 2018.11

3.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

18 Feb 2018

22:19

55

18

21
45

f

i

j

h

g

e

d

a

b

c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

21

21

The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.

Outdoor
unit

a2 a3

a1

a1

: Outdoor unit

a2

: Quiet mode active

a3

Measured ambient temperature

Indoor unit /
domestic
hot water
tank

b1

b2

b1

Indoor unit:

Floor-standing 

indoor 

unit 

with

integrated tank

b2

Water pressure

Space
operation
mode

c

: Heating

Disinfection
 / Powerful

d

: Disinfection mode active

: Powerful operation active

Date / time

e

Current date and time

Holiday

f

: Holiday mode active

Main zone

g3
g1

g4
g2

g1

Heat emitter type:

: Underfloor heating

: Fancoil unit

: Radiator

g2

Leaving water temperature setpoint

g3

Room thermostat type:

:  Daikin  user  interface  used  as  room

thermostat

: External control

▪ Hidden: Leaving water temperature control

g4

Measured room temperature

Item

Description

Additional
zone

h3
h1 h2

h1

Heat emitter type:

: Underfloor heating

: Fancoil unit

: Radiator

h2

Leaving water temperature setpoint

h3

Room thermostat type:

: External control

▪ Hidden: Leaving water temperature control

Domestic
hot water

i1 i2

i1

: Domestic hot water

i2

Measured tank temperature

Malfunction

j

 or 

: A malfunction occurred

See 

"6.1 To display the help text in case of a

malfunction" on page 11

 for more information.

3.2.2

Main menu screen

In the home screen, press 

 to open the main menu screen.

From the main menu, you can access the different setpoint screens
and submenus.

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Item

Description

 or 

Malfunctioning

Restriction: 

Only displayed if a malfunction

occurs.

See 

"6.1 To display the help text in case of

a malfunction" on page 11

 for more

information.

 Room

Restriction: 

Only displayed if a room

thermostat is connected to the indoor unit.

Set the room temperature.

 Main zone

Shows the applicable symbol for your main
zone emitter type.

Set the leaving water temperature for the
main zone.

 Additional zone

Restriction: 

Only displayed if there are two

leaving water temperature zones. Shows
the applicable symbol for your additional
zone emitter type.

Set the leaving water temperature for the
additional zone (if present).

 Space heating/

cooling

Shows the applicable symbol for your unit.

You cannot change the operation mode on
heating only models.

 Tank

Restriction: 

Only displayed if a domestic

hot water tank is present.

Set the domestic hot water tank
temperature.

Summary of Contents for Altherma EHVZ04S18DA6V

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G...

Page 2: ...the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for futu...

Page 3: ...he screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dia...

Page 4: ...ription Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water tempe...

Page 5: ...anges and proceed 3 3 Space heating control 3 3 1 Setting the space operation mode About space operation modes This unit is a heating only model The system can heat up a space but NOT cool down a spac...

Page 6: ...the next scheduled action to heat up the domestic hot water tank Then you can activate powerful operation The domestic hot water tank will start heating up the water to the Comfort temperature INFORM...

Page 7: ...You can program up to 6 actions each day 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon 4 Confirm the changes To copy the schedule to the other weekdays 1 Select Monday Mon Sat Wed Fri Thu Tue...

Page 8: ...n Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule INFORMATION Not all schedules can be renamed 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Se...

Page 9: ...ice C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes...

Page 10: ...er periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a prese...

Page 11: ...ature cannot be reached Increase the desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran ou...

Page 12: ...rs or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently venti...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P495247 1C 2018 11 Copyright 2017 Daikin 4P495247 1 C 00000003...

Reviews: