4 Installation
Installation manual
11
EHVZ04~16S18CB3V
Daikin Altherma – Low temperature split
4P401672-1D – 2017.04
X5M
A5P
78910
S2S S3S
2
Fix the cable with cable ties to the cable tie mountings.
4.5.8
To connect the domestic hot water pump
1
Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
X2M
X1M
K3M
K2M
35
34
1~
M
M2P
2
Fix the cable with cable ties to the cable tie mountings.
4.5.9
To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
X2M
X5M
A5P
X1M
A4P
K3M
K2M
29
X1M
YC
Y1
Y2
Y3
Y4
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.5.10
To connect the changeover to external
heat source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
X5M
A5P
A4P
X3 X4
L N
X2M
X1 X2
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.5.11
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
X5M
A5P
A8P
1
2
3
4
5
X801M
S6S
S7S
S8S
S9S
a
a
Installation of EKRP1AHTA is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.5.12
To connect the safety thermostat (normal
closed contact)
Main zone
1
Connect the safety thermostat (normal closed) cable to the
appropriate terminals as shown in the illustration below.