• Heating • Daikin Altherma low temperature split
4
• Daikin Altherma low temperature split • EHVH-C
2
Specifications
Notes
(1) Heatloss according to EN12897
(2) DB/WB 7ºC/6ºC - LWC 35ºC (DT=5ºC)
(3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
(4) The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow
(5) 15ºC-25ºC: BUH only, no heat pump operation = during commisioning
(6) Including PHE + back-up heater; excluding expansion vessel
(7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE
(8) See separate drawing for operation range
(9) For *RLQ* outdoor units \>55ºC BUH only, no heatpump operation
(10) For *RHQ* outdoor units \>50ºC BUH only, no heatpump operation
(11) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min
(12) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min
(13) Refer to operation range for detail for differences between *RHQ* and *RLQ* models
(14) PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
(15) For more details on current & voltage range, refer to the installation manual.
Water circuit
Piping connections diameter
inch
G 1"1/4 (female)
Safety valve
bar
3
Manometer
Yes
Drain valve / fill valve
Yes
Shut off valve
Yes
Air purge valve
Yes
Total water volume
l
4.4 (6)
4.8 (6)
5.8 (6)
4.5 (6)
5.5 (6)
Safety devices
Item
01
Thermal cutout (on indoor unit): 90-95ºC
PED
Category
Art3§3
Category I
Art3§3
Most critical part
Name
-
Plate heat exchanger
-
Ps*V
Bar*l
-
51.0 (0.000)
-
Water circuit -
Domestic hot water
side
Piping connections
Cold water in / Hot
water out
inch
G 1" FEMALE
Recirculation
connection
inch
G 1/2" FEMALE
2-2 Electrical Specifications
EHVH04S18C3V
EHVH08S18C3V
EHVH08S26C9W
EHVH16S18C3V
EHVH16S26C9W
Power supply
Voltage range
Min.
%
10
Max.
%
10
Wiring connections
Communication
cable
Quantity
3
Remark
2.5 mm²
Electric meter
Quantity
2
Preferential kWh
rate power supply
Quantity
Power: 2
Domestic hot water
pump
Quantity
2
Remark
Minimum 0.75 mm² (2A inrush, 1A continuous)
For connection with
R6T
Quantity
2
Remark
Minimum 0.75 mm²
For connection with
A3P
Remark
Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm²
For connection with
M2S
Quantity
3G
Remark
Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm²
For connection with
bottom plate heater
Quantity
2
Remark
Select diameter and type according to national and local regulations
For connection with
user interface
Quantity
2
Remark
0,75 mm² till 1,25 mm² (max length 500m)
For connection with
optional FWXV*
(demand input and
output)
Quantity
4
Remark
100 mA, minimum 0.75 mm²
Notes
For more details on current & voltage range, refer to the installation manual.
2-1 Technical Specifications
EHVH04S18C3V
EHVH08S18C3V
EHVH08S26C9W
EHVH16S18C3V
EHVH16S26C9W