• Altherma
TM
• Outdoor units
63
• Outdoor units • ERHQ011-016AAW1
6
Wiring diagram
6 - 1
Wiring diagram
2
6
ERHQ011-016AAW1
2TW57916-1C
A1P
Printed circuit board
A2P
Printed circuit board (INV)
A3P
Printed circuit board (Noise filter)
BS1
∼
BS4
Push button switch
C1
∼
C4
Capacitor
DS1
DIP switch
E1HC
Crankcase heater
E1H
Bottomplate heater
F1U
F1U
Fuse (31.5A 500V)
F2U
Fuse (31.5A 500V)
F3U
Fuse (T 6.3A / 250V)
F4U
Fuse (T 6.3A / 250V)
F5U
Fuse (T 6.3A / 250V)
F6U
Fuse (T 6.3A / 250V)
F7U
Fuse (T 5.0A / 250V)
F8U, F9U
Fuse (F 1.0A / 250V)
HAP (A1P)
Pilot lamp (Service monitor-green)
HAP (A2P)
Pilot lamp (Service monitor-green)
H1P
∼
7P (A1P)
Pilot lamp (Service monitor-orange)
K1M-K2M
Magnetic contactor
K1R (A1P)
Magnetic relay (Y1S)
K1R (A2P)
Magnetic relay
K2R (A1P)
Magnetic relay (Y2S)
K3R (A1P)
Magnetic relay (E1HC)
L1R
∼
L3R
Reactor
L4R
Reactor (For outdoor fan motor)
M1C
Motor (Compressor)
M1F
Motor (Fan) (upper)
M2F
Motor (Fan) (lower)
PS
Switching power supply
R1
∼
R4
Resistor
R1T
Thermistor (Air)
R2T
Thermistor (Discharge)
R3T
Thermistor (Suction)
R4T
Thermistor (Heat exchanger)
R5T
Thermistor (Heat exchanger middle)
R6T
Thermistor (liquid)
R7T
Thermistor (Fin)
S1NPH
Pressure sensor
S1PH
Pressure switch (high)
V1R
∼
V2R
Power module
V3R
Diode module
X1M
Terminal strip
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4 way valve)
Y3S
Solenoid valve
Z1C
∼
Z9C
Noise filter
Z1F
∼
Z4F
Noise filter
Q1DI
Earth leakage protector
Optional connector
X6A
Connector
X77A
Connector
X1Y
Connector
Notes:
1 This wiring diagram only applies to the outdoor unit
2 L: Live, N: Neutral,
g
: Field wiring
3
D
: Terminal strip
F
: Connector
G
M: Connection
R
: Protective earth (screw)
: Connector
p
: Noiseless earth
G
: Terminal
4 Refer to the option manual, for connecting wiring to x6A and X77A
5 Refer to the ’wiring diagram sticker’ (on the back of front plate) on how to
use BS1-BS4 and DS1 switch.
6 Do not operate the unit by short-circuiting protection device S1PH
7 Colors: BLK: black, RED: red, BLU: blue, WHT: white, YLW: yellow, ORG:
orange, BRN: brown, GRN: green
8 Confirm the method of setting the selector switches (DS1) by service
manual.
Factory setting of all switches: ’Off’
9
: Option
: Wiring dependent on model
arrow A
Indoor
Compressor
terminal position
Power supply
3N
∼
400V
50Hz
El. comp. Assy Front
Reactor box A
arrow B
Reactor terminal position
Only for *RHQ01*AAW18
EKBPHT16Y
Only for
*RHQ01*AAW1
Outdoor
Note: 4
Summary of Contents for Altherma EDLQ011-016AA6V3
Page 1: ...technical data EEDEN09 720 Altherma TM ...
Page 3: ...technical data EEDEN09 720 Altherma TM ...
Page 4: ... AlthermaTM AlthermaTM 4 A l t h e r A l t h e r R 4 1 0 A Heating only Heat pump ...
Page 6: ......
Page 7: ...technical data Part 1 4 ERHQ006 008AD EKHBH X008AA EEDEN09 720 Altherma TM ...
Page 8: ......
Page 20: ......
Page 35: ...technical data Part 2 4 ERHQ011 016AA ERHQ011 016AAW1 EKHBH X 016AB EEDEN09 720 Altherma TM ...
Page 36: ......
Page 52: ......
Page 68: ......
Page 84: ......
Page 176: ......
Page 196: ......
Page 216: ......
Page 236: ......
Page 237: ...technical data Part 4 4 EKHWS B EKHWE EKSOLHWAV1 EKRTW EKRTR EEDEN09 720 Altherma TM ...
Page 238: ......
Page 264: ......
Page 270: ......