background image

User reference guide

Daikin Altherma low temperature monobloc

English

User reference guide

Daikin Altherma low temperature monobloc

07CAV3
07CAV3
EKCB07CAV3
EK2CB07CAV3
EKMBUHCA3V3
EKMBUHCA9W1

Summary of Contents for Altherma EBLQ05CAV3

Page 1: ...er reference guide Daikin Altherma low temperature monobloc English User reference guide Daikin Altherma low temperature monobloc EBLQ05 07CAV3 EDLQ05 07CAV3 EKCB07CAV3 EK2CB07CAV3 EKMBUHCA3V3 EKMBUHCA9W1 ...

Page 2: ...amming schedules 17 4 7 3 Schedules Example 17 4 7 4 Predefined schedules Room temperature leaving water temperature main 18 4 7 5 Predefined schedules Leaving water temperature additional 18 4 7 6 Predefined schedules DHW tank temperature 18 4 8 Weather dependent operation 18 4 8 1 To set the weather dependent settings 18 4 9 Menu structure Overview user settings 20 4 10 Installer settings Tables...

Page 3: ...ences for the environment and human health For more information contact your installer or local authority Batteries are marked with the following symbol This means that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symb...

Page 4: ...ng cooling control How to control space heating cooling Setting the space operation mode Controlling the temperature Domestic hot water control How to control domestic hot water Reheat mode Scheduled mode Scheduled reheat mode Part Description Advanced usage Information about Quiet mode Holiday mode Reading out information Date time units of measurement contrast and backlight User profile and home...

Page 5: ...ission level Installer Defrost oil return mode is active Hot start mode is active Emergency operation is active 4 3 Basic usage 4 3 1 Using home pages About home pages You can use the home pages to read out and change settings that are meant for daily usage What you can see and do on the home pages is described where applicable Depending on your system layout the following home pages may be possib...

Page 6: ...ng only The system can heat up a space but NOT cool down a space You do NOT have to tell the system which space operation mode to use To tell the system which space operation to use you can do the following You can Location Check which space operation mode is currently used Home pages Room temperature Leaving water temperature main additional Set the space operation mode Menu structure Restrict wh...

Page 7: ...rature control 3 Only for room thermostat control Go to the main leaving water temperature home page LWT main and check the following Is displayed next to the set point Then leaving water set point and room temperature set point are Yes NOT linked You can set the leaving water set point on the home page No Linked by their preset values You can set the preset values in the menu structure 4 4 4 Room...

Page 8: ...ll return to Scheduled according to the overrule period Example Temporarily overruling the schedule AND changing the mode to preset value You have configured the following settings Settings Description Preset values Comfort heating 20 C Desired temperature when you are at home Eco heating 18 C Desired temperature When you are away During the night Schedule 07 00 Comfort You are at home Desired tem...

Page 9: ...n you can do the following 1 Set the overrule period Temperature lock to 2 hours 2 Go to the room temperature home page Room 3 Press to select Result For the next 2 hours the room will NOT be heated to the scheduled 20 C but to the preset value Eco 18 C After 2 hours the room will heat up again to the scheduled 20 C Advantage You save energy because you do NOT heat the room unnecessary and by the ...

Page 10: ... water temperature control means that you only control the leaving water temperature To control the leaving water temperature you can do the following You can Location Read out the desired leaving water temperature main additional Leaving water temperature home pages main additional Adjust overrule the leaving water temperature main Adjust the leaving water temperature additional Select which leav...

Page 11: ...der to avoid unsuccessful disinfection function at least allow the booster heater by the weekly program for minimum 4 hours starting from the scheduled start up of disinfection If the booster heater is restricted during disinfection this function will NOT be successful and the applicable warning AH will be generated INFORMATION In case of error code AH and no interruption of the disinfection funct...

Page 12: ...d the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water to a preset value example Storage eco 50 C Hot water is available again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day the cycle repeats In scheduled mode you can do the following You can Location Read out the active or next ...

Page 13: ...n you can do the following 1 Go to the DHW tank temperature home page Tank 2 Overrule the next scheduled action by changing from 55 C to 60 C Advantages You will have sufficient hot water comfortable You do NOT have to change the schedule easy You do NOT have to activate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW tank booster mode You can use the DH...

Page 14: ...le Select Automatic and press Program a schedule See 4 7 2 Using and programming schedules on page 17 Usage example Baby is sleeping in the afternoon If you are in the following situation You have programmed a quiet mode schedule During the night Level 3 most quiet During the day OFF to ensure the heating cooling capacity of the system However during the afternoon the baby is sleeping and you want...

Page 15: ...u have to switch to Adv end user level To activate or deactivate the holiday mode Prerequisite You have configured the holiday 1 Go to 2 1 Holiday Holiday 2 Do one of the following To activate select Yes and press To deactivate select No and press Usage example You go away during the winter If you are in the following situation In 2 days you go away for 2 weeks during the winter You want to save e...

Page 16: ...e and press Possible user profiles If user profile Detailed you can see and do more on the home pages User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual temperature 15 20 20 0 C 17 30 Actual temperature Room Scheduled Mon Tue To configure which home pages are made available to the end user Prerequisite You switched the permission level to Advanced end user 1 Go to 7 1 4 User set...

Page 17: ...Select for which control you want to use a schedule Example 5 1 Room temperature 3 Select for which operation mode you want to use a schedule Example 5 1 1 Heating 4 Select a predefined or user defined schedule and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user defined schedule 3 Change it 4 Save it Guidelines when programming 07 00 Set heati...

Page 18: ...cooling operation 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desired DHW tank temperature Preset value Storage eco Predefined 1 Mon Sun a b 00 Predefined 2 Mon Sun a b 00 00 Predefined 3 Mon Fri a b 00 Sat Sun a b 00 00 4 8 Weather dependent operation In ...

Page 19: ...d as for low outdoor temperatures warmer water is required In cooling this value should be higher than d as for low outdoor temperatures less cold water suffices d Desired leaving water temperature when the outdoor temperature equals or rises above the high ambient temperature Note in heating this value should be lower than c as for high outdoor temperatures less warm water is required In cooling ...

Page 20: ...nergy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater p...

Page 21: ...ing interruption will happen when selecting 6 0D 0 A 4 1 Domestic hot water Type Reheat only in case of a domestic hot water tank without an internal booster heater INFORMATION When the DHW tank booster mode is active the risk of space heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling inter...

Page 22: ...ity 12 49 pence kWh 7 4 5 17 49 6 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too low in cooling mode but ALWAYS according to your actual needs Each saved degree can save up to 6 of heating cooling costs Do NOT increase the desired room temperature to speed up space heating The space will NOT heat up faster When your sy...

Page 23: ...ndling Error history 8 3 To check the warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 8 4 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the...

Page 24: ...emperature Water temperature at the water outlet of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operates the product Applicable legislation All international European national and local directives laws regulations and or codes that are relevant and applica...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...4P405545 1C 2018 06 Copyright 2015 Daikin ...

Reviews: