4 Operation
User reference guide
10
EA23DA6V(7)+9W
Daikin Altherma 3 H F
4P556076-1A – 2021.09
1
Go to [1]:
Room
.
Room
1
2
Adjust the desired room temperature.
+
–
21
°C
1
a
b
Room
a
Actual room temperature
b
Desired room temperature
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1
Go to [1.1]:
Room
>
Schedule
.
2
Select
No
.
4.4.5
To change the desired leaving water
temperature
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Only adjust the leaving water temperature settings in case
of problems.
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
1
Go to [2]:
Main zone
or [3]:
Additional zone
.
Main zone
2
Additional zone
3
2
Adjust the desired leaving water temperature.
+
–
35
°C
2
a
b
Main zone
+
–
45
°C
3
a
b
Additional zone
a
Actual leaving water temperature
b
Desired leaving water temperature
If scheduling is on after changing the desired leaving water
temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired leaving water temperature will return to its scheduled
value whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off leaving water temperature scheduling
1
Go to one of the following:
▪ [2.1]:
Main zone
>
Schedule
▪ [3.1]:
Additional zone
>
Schedule
2
Select
No
.
To enable weather-dependent operation for the leaving water
temperature
See Weather dependent operation.
4.5
Domestic hot water control
4.5.1
About domestic hot water control
Depending on the DHW tank mode (installer setting), you use a
different domestic hot water control:
▪
Reheat only
▪
Sc reheat
▪
Schedule only
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the
Reheat only
or
Sc reheat
mode
is selected, it is recommended to program the start-up
of the disinfection function at least 4 hours later than
the last expected large hot water tapping. This start-up
can be set by installer settings (disinfection function).
▪ When the
Schedule only
mode is selected, it is
recommended to program an
Eco
action 3 hours before
the scheduled start-up of the disinfection function to
preheat the tank.