5 Energy saving tips

Operation manual

14

EA23DA6V(7)+9W

Daikin Altherma 3 H F

4P556074-1A – 2021.09

4.9

Installer settings: Tables to be
filled in by installer

4.9.1

Configuration wizard

Setting

Fill in…

System

Indoor unit type

 (read only)

Backup heater type

 [9.3.1]

Domestic hot water

 [9.2.1]

Emergency

 [9.5]

Number of zones

 [4.4]

Backup heater

Voltage

 [9.3.2]

Configuration

 [9.3.3]

Capacity step 1

 [9.3.4]

Additional capacity step 2

[9.3.5] (if applicable)

Main zone

Emitter type

 [2.7]

Control

 [2.9]

Setpoint mode

 [2.4]

Schedule

 [2.1]

Additional zone

 (only if [4.4] = 1)

Emitter type

 [3.7]

Control

 (read only) [3.9]

Setpoint mode

 [3.4]

Schedule

 [3.1]

Tank

Heat up mode

 [5.6]

Comfort setpoint

 [5.2]

Eco setpoint

 [5.3]

Reheat setpoint

 [5.4]

4.9.2

Settings menu

Setting

Fill in…

Main zone

Thermostat type

 [2.A]

Additional zone

 (if applicable)

Thermostat type

 [3.A]

Information

Dealer information

 [8.3]

5

Energy saving tips

Tips about room temperature

▪ Make sure the desired room temperature is NEVER too high, but

ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

underfloor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If

necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature  until  the  next  scheduled  action. 

Example: 

When

you have a party, or when you are leaving for a couple of hours.

▪ For longer periods: You can use the holiday mode.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(ONLY in scheduled mode).

▪ Program to heat up the DHW tank to a preset value (

Comfort

 =

higher  DHW  tank  temperature)  during  the  night,  because  then
space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  NOT  sufficient,

program to additionally heat up the DHW tank to a preset value
(

Eco

 = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  ONLY  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

Summary of Contents for Altherma EAVZ16S18DA6V

Page 1: ...Operation manual Daikin Altherma 3 H F English Operation manual Daikin Altherma 3 H F EAVZ16S18DA6V 7 EAVZ16S23DA6V 7 EAVZ16S18DA9W EAVZ16S23DA9W...

Page 2: ...filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation se...

Page 3: ...oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery B...

Page 4: ...ng cooling heat pump model is installed Produce domestic hot water INFORMATION Cooling is only applicable in case a conversion kit EKHVCONV is installed 3 1 Components in a typical system layout d a b...

Page 5: ...side of the screen Turn the right dial Navigate through the possible values and settings Press the right dial Confirm your choice and go to the next menu item 4 2 Possible screens Overview The most c...

Page 6: ...t Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a malfunction occurs See 7 1 To display the help text in case of a malfunction 415...

Page 7: ...alue Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functiona...

Page 8: ...l it can both heat up and cool down a space You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation...

Page 9: ...water corresponding to a schedule The best time to allow the tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2...

Page 10: ...st of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The Advanced use...

Page 11: ...programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Se...

Page 12: ...e Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedul...

Page 13: ...edule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection s...

Page 14: ...hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs ONLY in scheduled mode Program to heat up the DHW t...

Page 15: ...ture See 4 4 2 To change the desired room temperature 48 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the...

Page 16: ...text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with the air purge function of the unit to be performed by the installer If you purge air from...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P556074 1A 2021 09 Copyright 2018 Daikin 4P556074 1 A 0000000 Verantwortung f r Energie und Umwelt...

Reviews: