7 Installation
Installer reference guide
24
EPGA11~ EA9W
Daikin Altherma – Low temperature split
4P556075-1 – 2019.02
2
Remove the user interface panel. Open the hinges at the top
and slide the top panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the panel to prevent damage.
2
1
1
3
3
If necessary, remove the front plate. This is, for example,
necessary in the following cases:
▪
"7.2.5 To lower the switch box on the indoor unit" on
page 24
▪
"7.4.4 To connect the drain hose to the drain" on page 26
▪ When you need access to the high voltage switch box
2×
T25
7.2.4
To open the switch box cover of the
indoor unit
4×
T25
4×
T25
7.2.5
To lower the switch box on the indoor unit
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite:
The user interface panel and front panel have been
removed.
1
Remove the top panel that keeps the switch box into place at
the top of the unit.
2
Tilt the switch box to the front and lift it out of its hinges.
1
2
2×
T25
3
Place the switch box lower on the unit. Use the 2 hinges located
lower on the unit.
3
3