4
|
Operation
User reference guide
44
EWSAH/X06(U)D
Daikin Altherma 3 WS
4P675766-1 – 2022.04
To rename the schedule
1
Select the name of the current schedule.
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
2
Select
Rename
.
Delete
Rename
Select
3
(optional) To delete the current schedule name, browse
through the character list until
←
is displayed, then press to
remove the previous character. Repeat for each character of
the schedule name.
4
To name the current schedule, browse through the character
list and confirm the selected character. The schedule name can
contain up to 15 characters.
5
Confirm the new name.
INFORMATION
Not all schedules can be renamed.
Usage example: You work in a 3-shift system
If you work in a 3-shift system, you can do the following:
1
Program 3 room temperature schedules and give them appropriate names.
Example:
EarlyShift, DayShift and LateShift
2
Select the schedule that you currently want to use.
4.9 Weather-dependent curve
4.9.1 What is a weather-dependent curve?
Weather-dependent operation
The unit operates 'weather-dependent' if the desired leaving water or tank
temperature is determined automatically by the outdoor temperature. It therefore
is connected to a temperature sensor on the North wall of the building. If the
outdoor temperature drops or rises, the unit compensates instantly. Thus, the unit
does not have to wait for feedback by the thermostat to increase or decrease the
temperature of the leaving water or tank. Because it reacts more quickly, it
prevents high rises and drops of the indoor temperature and water temperature at
tap points.
Advantage
Weather-dependent operation reduces energy consumption.