Daikin Altherma 3 R F+W Operation Manual Download Page 6

4 Operation

Operation manual

6

EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V

+6V+9W

Daikin Altherma 3 R F+W

4P629084-2 – 2020.08

Item

Description

i

Main zone

i1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

21

Measured room temperature

(a)

i4

35

Leaving water temperature setpoint

(a)

j

Holiday mode

Holiday mode active

k Additional zone

k1

Installed room thermostat type:

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

k2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

k3

45

Leaving water temperature setpoint

(a)

l

Malfunction

A malfunction occurred.

See 

"7.1 To display the help text in case of a

malfunction" 

[

4

 15] for more information.

(a)

If the corresponding operation (for example: space heating) is not
active, the circle is greyed out.

4.2.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"7.1 To display the help text in

case of a malfunction" 

[

4

 15] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a

dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the indoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

[4]

 

Space heating/

cooling

Shows the applicable symbol of your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.

[5]

 

Tank

Set the domestic hot water tank
temperature.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or
off.

[D]

 

Wireless

gateway

Restriction: 

Only displayed if a

wireless LAN (WLAN) is installed.

Contains settings needed when
configuring the Daikin Residential
Controller app.

4.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

35

°C

2

Main zone

Summary of Contents for Altherma 3 R F+W

Page 1: ...3 R F W EHBH04E 6V EHBH08E 6V EHBH08E 9W EHBX04E 6V EHBX08E 6V EHBX08E 9W EHVH04S U 18E 6V EHVH04S U 23E 6V EHVH08S U 18E 6V EHVH08S U 23E 6V EHVH08S18E 9W EHVH08S23E 9W EHVX04S18E 3V EHVX04S18E 6V EH...

Page 2: ...he documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Chec...

Page 3: ...battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste...

Page 4: ...a DHW tank is installed 3 1 Components in a typical system layout d a b c e f g B C A A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Garage a Outdoor unit...

Page 5: ...lues c3 Screen with weather dependent curve c4 Screen with schedule 4 2 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setp...

Page 6: ...g cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a ma...

Page 7: ...een Go through the list of settings Change the value Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can...

Page 8: ...options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month accord...

Page 9: ...tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tan...

Page 10: ...evel Browse through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed Advanced user pin code The Advanced user pin code is 1234 Addit...

Page 11: ...lid until the next programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the o...

Page 12: ...elect Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each charac...

Page 13: ...tivation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation...

Page 14: ...emperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature U...

Page 15: ...is displayed on the screen 7 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired roo...

Page 16: ...k if or is displayed on the home screen of the user interface See 7 1 To display the help text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...4P629084 2 2020 08 Copyright 2020 Daikin 4P629084 2 0000000S Verantwortung f r Energie und Umwelt...

Reviews: