![Daikin Altherma 3 R ECH2O Installation And Operating Manual Download Page 23](http://html.mh-extra.com/html/daikin/altherma-3-r-ech2o/altherma-3-r-ech2o_installation-and-operating-manual_501184023.webp)
3 Set-up and installation
Installation and operating manual
23
Daikin Altherma EHS(X/H)(B)-D
Daikin Altherma 3 R ECH
₂
O
008.1451099_00 – 07/2020
3.7.2
Position of the PCBs and terminal strips
3‒32 Position of the PCBs and terminal strips
a
Switch box
b
Switch box cover
A1P
PCB (heat pump basic control)
RoCon+ B1
Controller control panel
RoCon BM2C
PCB (basic controller module)
RTX-EHS
PCB (backup heater)
X1
Terminal strip for backup heater mains connection
XAG1
Heat pump outdoor unit plug connection
XTA1
Outdoor temperature sensor terminal strip T
A
3.7.3
Mains connection
A flexible cable for the mains connection is already connected inside
the device.
1
Check the supply voltage (~230 V, 50 Hz).
2
Disconnect the junction box of the domestic installation.
3
Connect the cable for connecting the indoor unit to the mains to
the domestic installation's junction box (isolator according to
EN 60335-1) via an all-pole separating main switch to be
installed in the building. Ensure that the polarity is correct.
3.7.4
General information on the electrical
connection
1
Check the supply voltage.
2
Set the mains switch to "Off".
3
Switch off the circuit breaker in the junction box of the domestic
power supply.
4
Open the switch box (see
14]).
5
Insert the cable through one of the cable glands into the interior
of the switch box. When cutting and laying cables to be
connected, make sure that the switch box can be brought into
the service position without any tension.
3‒33 Cable gland
6
Make electrical connections according to
22] and the following sections.
7
Effective strain relief in the switch box by means of cable ties
must be ensured for all cables connected to the indoor unit and
their holding force checked.
3‒34 Establishing and checking the strain relief
8
After the installation is complete: Close the switch box again
and, if necessary, move it to the normal position.
3.7.5
Connecting the heat pump outdoor unit
INFORMATION
A
separate
manual
containing
instructions
about
installation and operation is included with this component.
1
Follow the installation steps in
"3.7.4 General information on the
2
Connect the heat pump outdoor unit to the XAG1 terminal strip.
Summary of Contents for Altherma 3 R ECH2O
Page 342: ......
Page 343: ......
Page 344: ...008 1451099_00 07 2020 Copyright Daikin Verantwortung für Energie und Umwelt ...