Daikin Altherma 3 H HT F+W User Reference Manual Download Page 1

User reference guide 

Daikin Altherma 3 H HT F+W

ETVH16S18DA6V(G)
ETVH16S23DA6V(G)
ETVH16S18DA9W(G)
ETVH16S23DA9W(G)
ETVX16S18DA6V(G)
ETVX16S23DA6V(G)
ETVX16S18DA9W(G)
ETVX16S23DA9W(G)

ETBH16DA6V
ETBH16DA9W
ETBX16DA6V
ETBX16DA9W

Summary of Contents for Altherma 3 H HT F+W

Page 1: ...ence guide Daikin Altherma 3 H HT F W ETVH16S18DA6V G ETVH16S23DA6V G ETVH16S18DA9W G ETVH16S23DA9W G ETVX16S18DA6V G ETVX16S23DA6V G ETVX16S18DA9W G ETVX16S23DA9W G ETBH16DA6V ETBH16DA9W ETBX16DA6V E...

Page 2: ...d out information 30 Possible read out information 30 4 6 Space heating cooling control 31 4 6 1 About space heating cooling control 31 4 6 2 Setting the space operation mode 31 4 6 3 Determining whic...

Page 3: ...in case of a malfunction 57 7 2 To check the malfunction history 57 7 3 Symptom You are feeling too cold hot in your living room 58 7 4 Symptom The water at the tap is too cold 58 7 5 Symptom Heat pum...

Page 4: ...read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Booster heater capacity 9 4 1 if applicable Backup heater Voltage 9 3 2 Configurat...

Page 5: ...Altherma 3 H HT F W 4P586456 1 2019 07 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 1 2 Settings menu Setti...

Page 6: ...vanced user You can read out and edit more information To change the user permission level 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level Browse th...

Page 7: ...room frost protection if enabled will remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze preve...

Page 8: ...ditional zone a Actual leaving water temperature b Desired leaving water temperature To change the weather dependent curve for the space heating cooling zones 1 Go to the applicable zone Zone Go to Ma...

Page 9: ...rve before changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go to off...

Page 10: ...e you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the domestic hot water temperature 50 C 5 a b Tank a Actual...

Page 11: ...WD curve before changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increase or decrease the slope offset When slope is selected set slope and go...

Page 12: ...th the following symbol This means that electrical and electronic products may NOT be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system trea...

Page 13: ...staller settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete se...

Page 14: ...eating app to control and monitor the status of your Daikin Altherma heat pump system For more information see http www onlinecontroller daikineurope com Breadcrumbs Breadcrumbs example 4 3 help you t...

Page 15: ...serious injury WARNING FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury NOTICE Indicates a situation that could result in equipment or property damage INF...

Page 16: ...models Heating only models conversion kit 3 3 1 Components in a typical system layout g A d b a f e c B C A Main zone Example Living room B Additional zone Example Bedroom C Technical room Example Gar...

Page 17: ...how the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occ...

Page 18: ...dial Choose a menu item Press the left dial Confirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help...

Page 19: ...ta Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cooling Tank 1 4 Antifrost Activation Ro...

Page 20: ...a 3 H HT F W 4P586456 1 2019 07 4 3 Possible screens Overview The most common screens are as follows a OR b c c2 c4 c1 c3 a Home screen b Main menu screen c Lower level screens c1 Setpoint screen c2 D...

Page 21: ...list of the main menu Go to the main menu screen Enable disable breadcrumbs Item Description a Domestic hot water a1 Domestic hot water a2 55 Measured tank temperature a b Disinfection Powerful Disin...

Page 22: ...om thermostat installed or set Unit operation is decided based on the leaving water temperature regardless of the actual room temperature and or heating demand of the room i2 Installed heat emitter ty...

Page 23: ...ikin Altherma 3 H HT F W 4P586456 1 2019 07 Item Description l Malfunction A malfunction occurred See 7 1 To display the help text in case of a malfunction 457 for more information a If the correspond...

Page 24: ...ed Human Comfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leav...

Page 25: ...in Altherma 3 H HT F W 4P586456 1 2019 07 Submenu Description A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation...

Page 26: ...tional zone 5 Tank temperature screen 50 C 5 Tank Explanation a1 d d e d e c a2 b1 b2 Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically appl...

Page 27: ...HT F W 4P586456 1 2019 07 4 3 4 Detailed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go...

Page 28: ...ed the corresponding temperature icon in the home screen will be greyed out Room temperature control 1 6 bar 55 19 42 18 a 1 6 bar 55 19 42 18 b a Room temperature control ON b Room temperature contro...

Page 29: ...ill remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain activ...

Page 30: ...Malfunction history 8 3 Dealer information Contact helpdesk number 8 4 Sensors Room tank or domestic hot water outside and leaving water temperature if applicable 8 5 Actuators Status mode of each ac...

Page 31: ...n mode to use To determine if a heating cooling heat pump model is installed 1 Go to 4 Space heating cooling 2 Check if 4 1 Operation mode is listed and editable If so a heating cooling heat pump mode...

Page 32: ...an option Reversible Not restricted Heating only Restricted Cooling only Restricted 4 Confirm the changes Example Changeover restrictions When Restriction During cold season Example October November...

Page 33: ...djust the desired room temperature 1 Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a Actual room temperature b Desired room temperature If scheduling is on after changing t...

Page 34: ...mperature b Desired leaving water temperature If scheduling is on after changing the desired leaving water temperature The temperature will stay the same as long as there is no scheduled action The de...

Page 35: ...ctions are recommended When the Reheat only or Schedule reheat mode is selected it is recommended to program the start up of the disinfection function at least 4 hours later than the last expected lar...

Page 36: ...n frequent and long space heating cooling interruption will happen when selecting the following Tank Heat up mode Reheat only INFORMATION When the DHW tank mode is reheat the risk for capacity shortag...

Page 37: ...a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is availab...

Page 38: ...displayed on the home screen powerful operation is active Activate or deactivate Powerful operation as follows 1 Go to 5 1 Tank Powerful operation 2 Turn powerful operation Off or On Usage example Yo...

Page 39: ...In schedule if domestic hot water tank mode is Schedule only Schedule reheat Eco setpoint Reheat setpoint If domestic hot water tank mode is Schedule reheat To define energy prices Only possible if Bi...

Page 40: ...our electricity supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price fo...

Page 41: ...s used in this example are NOT accurate Data Price kWh Gas price 4 08 Electricity price 12 49 Renewable heat incentive per kWh 5 Calculation of the gas price Gas price Actual gas price Incentive kWh 0...

Page 42: ...eaving water temperature for the main zone in heating mode 2 3 Main zone Cooling schedule Program the desired leaving water temperature for the main zone in cooling mode 3 2 Additional zone Heating sc...

Page 43: ...room thermostat control is active If leaving water temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week sche...

Page 44: ...ined 1 2 Select Edit Delete Edit Copy 3 Use the left dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker...

Page 45: ...fined 1 2 Select Copy Delete Edit Copy Result Next to the copied day C is displayed 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat W...

Page 46: ...f the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is display...

Page 47: ...6V 9W G ETBH X16DA6V 9W Daikin Altherma 3 H HT F W 4P586456 1 2019 07 1 Program 3 room temperature schedules in heating mode and give them appropriate names Example EarlyShift DayShift and LateShift 2...

Page 48: ...pendent curve To be able to compensate for differences in temperature the unit relies on its weather dependent curve This curve defines how much the temperature of the tank or leaving water must be at...

Page 49: ...changes and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the lea...

Page 50: ...X1 is unequally higher than the preferred temperature at X2 When offset is changed the new preferred temperature at X1 is equally higher as the preferred temperature at X2 c Slope d Offset e Selected...

Page 51: ...in zone Setpoint mode WD heating fixed cooling OR Weather dependent Main zone Cooling 2 4 Main zone Setpoint mode Weather dependent Additional zone Heating 3 4 Additional zone Setpoint mode WD heating...

Page 52: ...une the weather dependent curve slope offset curve The following table describes how to fine tune the weather dependent curve of a zone or tank You feel Fine tune with slope and offset At regular outd...

Page 53: ...check if quiet mode is active If is displayed on the home screen quiet mode is active To program a quiet mode schedule Restriction Only possible if enabled by the installer 1 Go to 7 4 2 User setting...

Page 54: ...019 07 To configure the holiday 1 Activate the holiday mode Go to 7 3 1 User settings Holiday Activation Activation Till 7 3 1 From Select On 2 Set the first day of your holiday Go to 7 3 2 From Selec...

Page 55: ...or a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in lower energy consumption...

Page 56: ...equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mi...

Page 57: ...n In case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the...

Page 58: ...the heat emitter type See 4 6 5 To change the desired leaving water temperature 433 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 4 9 Weather dependent curve 4...

Page 59: ...ting is reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH normal DHW off space heating operates as norm...

Page 60: ...ore you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want...

Page 61: ...A6V 9W Daikin Altherma 3 H HT F W 4P586456 1 2019 07 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit outdoor unit DHW tank contact your ins...

Page 62: ...HT F W 4P586456 1 2019 07 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislat...

Page 63: ...duct or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or applicati...

Page 64: ...4P586456 1 2019 07 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...

Reviews: