3 Operation

Operation manual

4

EGSAH/X06+10DA9W(G)

Daikin Altherma 3 GEO

4P569812-1 – 2019.02

Item

Description

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

3.2

Possible screens: Overview

The most common screens are as follows:

+

a

b

c

c2

c1

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

3.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

26 Feb 2019

22:19

55

21
45

h

j

i1
i2

i3

18

b

c

e3

e2

f1

e1

g2 g3 g4

f2

g1

a2

a1

d

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(1)

b Current date and time

c Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

d Space operation mode

Cooling

Heating

e Outdoor / quiet mode

e1

6

Measured outdoor temperature

(1)

e2

Quiet mode active

e3

Outdoor brine piping

f

Indoor unit / domestic hot water tank

f1

Floor-standing indoor unit with integrated tank

f2

Water pressure

g Main zone

g1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

g2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

g3

21

Measured room temperature

(1)

g4

45

Leaving water temperature setpoint

(1)

h Holiday mode

Holiday mode active

i

Additional zone

i1

Installed room thermostat type:

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

18

Leaving water temperature setpoint

(1)

Summary of Contents for Altherma 3 GEO EGSAH06DA9W

Page 1: ...Operation manual Daikin Altherma 3 GEO English Operation manual Daikin Altherma 3 GEO EGSAH06DA9W EGSAH10DA9W EGSAX06DA9W G EGSAX10DA9W G ...

Page 2: ...eep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you must read before installing Format Paper in the box of the unit Operation manual Quick guide for basic usage Format Paper in the box of the unit User reference guide Detailed step by ...

Page 3: ...icator b LCD screen c Dials and buttons Status indicator The LEDs of the status indicator light up or blink to show the operating mode of the unit LED Mode Description Blinking blue Standby The unit is not in operation Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 6 1 To display the help text in case of a malfunction on page 11 for more info...

Page 4: ...5 Measured tank temperature 1 b Current date and time c Disinfection Powerful Disinfection mode active Powerful operation mode active d Space operation mode Cooling Heating e Outdoor quiet mode e1 6 Measured outdoor temperature 1 e2 Quiet mode active e3 Outdoor brine piping f Indoor unit domestic hot water tank f1 Floor standing indoor unit with integrated tank f2 Water pressure g Main zone g1 Ins...

Page 5: ...de or cooling mode Tank Set the domestic hot water tank temperature User settings Gives access to user settings such as holiday mode and quiet mode Information Displays data and information about the indoor unit Installer settings Restriction Only for the installer Gives access to advanced settings Commissioning Restriction Only for the installer Perform tests and maintenance User profile Change t...

Page 6: ...r temperature is set by your installer in accordance with the heat emitter type Only adjust the leaving water temperature settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the se...

Page 7: ...ditional menu items for the user are now visible 3 6 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule Example You want to program the following schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 Prerequisite The room temperature schedule is o...

Page 8: ...ue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24...

Page 9: ...g Operation mode Operation mode schedule 5 Tank Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve type 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours B User profile C Operation Room Space heating cool...

Page 10: ...e Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away during your holiday Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Comfort higher D...

Page 11: ...e 6 Possible cause Corrective action The weather dependent curve is set incorrectly Adjust the weather dependent curve See the user reference guide 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of unusual high consumption If you immediately need domestic hot water activate the DHW tank Powerful operation However this consume...

Page 12: ... collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge air is sufficiently ventilated Reason Refrigerant might leak into the water circuit and subsequently into the room when you purge air from the heat emitters or collectors 7 Disposal NOTICE Do NOT try to dismantle the system yourse...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P569812 1 2019 02 Copyright 2019 Daikin 4P569812 1 0000000T ...

Reviews: