3 Operation

Operation manual

4

D2C18ND0 D2HND012/18A5AA

Wall-mounted condensing boiler

3P469438-9H – 2018.05

Button/Dial

Function

Description

Mode /
Reset

Mode

Change mode between summer,
winter, central heating only, standby
and full-off.

Reset

Reset the lockout error.

Cancel /
Back

Cancel

Cancel changes.

Back

Go back to the parent menu.

Menu / Enter Menu

Enter the menu function.

Enter

Passing on to the next level in the
menu structure.

Confirm

Confirmation of changes.

Left dial

User
interaction
level

Central heating temperature setpoint.

This is either the central heating flow
temperature, the room temperature,
or the virtual room temperature,
depending on the system
configuration.

Menu level

Selection of info, user, service menu.

Right dial

User
interaction
level

Domestic hot water temperature
setpoint.

Menu level

▪ Selection parameter index.

▪ Change parameter values.

3.1.2

LCD screen

LCD  screen  is  the  monitor  of  the  user  interface.  You  can  see  the
boiler  operation  mode,  setpoints,  information  about  actuators  and
menu parameters on this screen.

The  LCD  screen  has  a  sleeping  function.  After  one  minute  of  non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.

When you interact with the user interface, the LCD screen will show
the  home  screen  of  the  active  operation  mode  and  the  related
setpoint, depending on the system configuration (see 

"3.3.3 Possible

operation modes" on page 5

).

Status icons

Meaning of icons that appear on the LCD screen:

Icon

Description

Operation mode: Standby mode

Domestic hot water operation enabled

Domestic hot water comfort mode is enabled

Central heating operation enabled

Room temperature

Outdoor sensor connection

Central heating ECO mode enabled

Network connection

Info menu

User settings menu

Service settings menu

3.1.3

Status indicator

The status indicator gives first level feedback on the operation mode
and status of the boiler.

Status

Description

Standby

When there is no heat demand, the status
indicator shows this with a kind of breathing
pulsation of the blue and white LED.

Flame

At the moment flame ignites for central heating or
domestic hot water, the ring flashes to its
maximum, then constantly keeps glowing during
burner operation.

Error

The status indicator will go into error mode when a
warning, lockout or blocking error occurs (see

"3.4 Error handling" on page 7

). During the error

condition the status indicator continuously shows
the red blinking LED.

NOTICE

In  warning  error,  the  status  indicator  colour  turns  to  blue
while the boiler is operating.

3.2

Operating the unit

3.2.1

To switch ON the unit

1

Connect the unit to the main power supply.

2

Press the "Mode" button for 5 seconds to switch ON the unit.

3

After  that,  you  can  select  an  operation  mode  by  pressing  the
"Mode" button shortly.

Use of the unit is explained in following parts of this manual.

3.2.2

About the low water temperature function

The  low  water  temperature  function  is  a  safety  function  that  takes
place  at  first  central  heating  operation  after  each  power  supply
interruption and at first central heating operation after each 90 days.
When  this  function  is  active,  boiler  operates  according  to  a  defined
set  value  for  around  15  minutes  and  the 

  icon  blinks.  After  this

function is ended, normal operation goes on.

INFORMATION

Low  water  temperature  function  is  a  safety  function  and  it
cannot be disabled.

3.2.3

About the electronic gas adaptive system
calibration

The  electronic  gas  adaptive  system  calibrates  itself  in  pre-
determined  intervals.  First  calibration  takes  place  just  after  first
burner activation after each power ON. Calibration process duration
is  around  60  seconds  and  the 

  icon  blinks.  After  calibration  is

ended,  boiler  modulates  to  required  capacity.  Calibration  process
has no effect on boiler operation.

Calibration  can  also  take  place  in  summer  mode  without  water
tapping  if  proper  conditions  are  met.  In  other  words,  boiler  may
operate itself for a short duration in summer mode even though there
is no domestic hot water demand. This is an expected behavior.

3.3

Basic usage

3.3.1

About the home screen

It is the screen that is displayed after activating the LCD screen with
one of the dials or buttons. You can use the home screen to read out
settings that are meant for daily use. What you can see on the home
screen depends on your system configuration.

The following home screens may be possible:

▪ Room temperature (Daikin room thermostat connected)

▪ Central heating set temperature

Summary of Contents for Altherma 3 C Gas W D2HND-A5A

Page 1: ...eration manual Wall mounted condensing boiler English Manuel d utilisation Chaudi re murale condensation Fran ais Operation manual Wall mounted condensing boiler D2C18ND024A5AA D2HND012A5AA D2HND018A5...

Page 2: ...the unit See table below Model Type Domestic hot water supply D2C18ND024A5AA D2C18ND024 Instantaneous D2HND012A5AA D2HND012 Heating only D2HND018A5AA D2HND018 Heating only A control unit which contain...

Page 3: ...Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is...

Page 4: ...domestic hot water the ring flashes to its maximum then constantly keeps glowing during burner operation Error The status indicator will go into error mode when a warning lockout or blocking error occ...

Page 5: ...ter operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well a...

Page 6: ...ing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating operation mode i...

Page 7: ...ICE When not using the boiler we strongly recommend not to cut off the electric supply to the boiler 3 3 10 About Energy Metering Function This function provides user to read electricity and gas consu...

Page 8: ...ric energy consumption Domestic hot water Last month kWh Description short Unit F42 d Electric energy consumption Domestic hot water Current month kWh F43 d Electric energy consumption Domestic hot wa...

Page 9: ...For this parameter value to be active reducing mode has to be enabled by your service agent otherwise central heating mode will not be activated when there is no heat demand U07 When On Off room therm...

Page 10: ...lution 10 64 Gas valve circuit error Perform reset If problem repeats contact your service agent 10 65 Gas valve current error Perform reset If problem repeats contact your service agent 11 64 Ignitio...

Page 11: ...the system pressure to 0 8 bar HJ 10 Water pressure sensor fault Contact your service agent J6 01 Flow temperature sensor overheating Can be a blocking error or a lockout error Check the valves of the...

Page 12: ...fage central Le type d alimentation d eau chaude peut tre instantan ou par l interm diaire d un r servoir de stockage d eau chaude Les chaudi res uniquement chauffantes ne fournissent pas d eau chaude...

Page 13: ...ntenance ou une r paration vous m me Faites appel un agent d entretien qualifi ATTENTION N utilisez pas de sprays de solvants d agents de nettoyage chlor s de peinture et d adh sifs proximit de l unit...

Page 14: ...s param tres du menu L cran cristaux liquides dispose d une fonction de veille Au bout d une minute de non interaction avec l interface utilisateur l cran s assombrit Appuyer sur un des boutons ou tou...

Page 15: ...eau chaude sanitaire Il s agit du comportement habituel 3 3 Utilisation de base 3 3 1 propos de l cran d accueil Il s agit de l cran qui s affiche apr s l activation de l cran cristaux liquides l aid...

Page 16: ...consigne de la temp rature peuvent tre modifi s l aide des molettes gauche droite Modification du point de consigne de la temp rature du chauffage central 1 Tournez la molette gauche en tant l cran d...

Page 17: ...chauffage central est activ REMARQUE En cas de conception mauvaise ou inadapt e du circuit de chauffage central qui provoquerait un d gagement de chaleur inad quat dans l espace de s jour activer le m...

Page 18: ...le statut de l indicateur de statut est affect Cependant veuillez noter que toutes les erreurs n ont pas le m me effet sur l interface utilisateur et l indicateur de statut Type d erreur Fonctionnemen...

Page 19: ...mation d nergie lectrique eau chaude sanitaire mois actuel kWh F43 d Consommation d nergie lectrique eau chaude sanitaire ann e actuelle kWh a Ne s applique pas si le capteur n est pas raccord b Valeu...

Page 20: ...ture int rieure virtuelle s il n y a pas de demande de chauffage Note Pour que cette valeur de param tre soit active le mode de r duction doit tre activ par votre agent d entretien autrement le mode c...

Page 21: ...olets la nuit Ne cachez pas de radiateurs derri re de grands meubles c est dire un canap un bureau etc Il faut garder une distance d au moins 50 cm sinon l air chaud ne peut pas circuler et la pi ce n...

Page 22: ...circuler Votre chaudi re fonctionnera nouveau au bout d un moment Si le probl me se r p te contactez votre agent d entretien 8H 65 Diff rence de temp rature d part retour trop lev e Veillez ce que les...

Page 23: ...xion du thermostat d ambiance Opentherm est d fectueuse Votre chaudi re continuera fonctionner mais le thermostat d ambiance Opentherm est hors service Contactez votre agent d entretien U4 66 Expirati...

Page 24: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469438 9H 2018 05...

Reviews: