![background image](http://html1.mh-extra.com/html/daikin/4mwxm52a2v1b/4mwxm52a2v1b_installers-reference-manual_3583107053.webp)
9
|
Electrical installation
Installer reference guide
53
4MWXM-A
R32 Split series
4P678385-1A – 2022.02
8
Pass the wiring through the cutout on the bottom of the protection plate.
9
Make sure that the electrical wiring does NOT make contact with the gas
piping.
2×
1 2 3
a
b
d
c
e
f
1 2
L N
3
a
Terminal for indoor unit A
b
Terminal for indoor unit B
c
Terminal for indoor unit C
d
Terminal for DHW tank
e
Power supply terminal
f
Wire retainer
10
Reattach the switch box cover and the service cover.