![background image](http://html1.mh-extra.com/html/daikin/3mxm40a2v1b9/3mxm40a2v1b9_installers-reference-manual_3667182054.webp)
9
|
Electrical installation
Installer reference guide
54
2MXM-A9, 3MXM-A9, 4MXM-A9, 5MXM-A9
R32 Split series
4P600463-7G – 2022.09
1
1×
2
2
Strip insulation (20 mm) from the wires.
a
b
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
3
Connect the wires between the indoor and outdoor units so that the terminal
numbers match. Make sure to match the symbols for piping and wiring.
4
Make sure to connect correct wiring to correct room.
e
-B
e
-E
e
-C
e
-D
a
-A
e
-A
a
-C
a
-D
a
-E
a
-B
b
c
d
a
Terminal for room (A, B, C, D, E)*
b
Circuit breaker
c
Residual current device
d
Power supply wire
e
Interconnection wire for room (A, B, C, D, E)*
*May differ depending on the model.
5
Tighten the terminal screws securely using a Philips screwdriver.
6
Check that the wires do not disconnect by pulling them lightly.
7
Firmly secure the wire retainer to avoid external stress on wire terminations.
8
Pass the wiring through the cutout on the bottom of the protection plate.
9
Make sure the electrical wiring does not contact with the gas piping.