Si121557E
Outdoor Unit
Removal Procedure
25
1.6
Coils / Thermistors
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Remove the screw and
remove the four way
valve coil.
2
Disconnect the relay
connector for the high
pressure switch lead
wire.
3
Remove the high
pressure switch lead
wire.
(R15743)
Four way
valve coil
High pressure
switch lead wire
(R13768)
High pressure
switch lead
wire
(R13703)
High pressure switch