![background image](http://html.mh-extra.com/html/daikin/2mx45bgxv1/2mx45bgxv1_technical-manual_501079025.webp)
21
Engineering & Physical Data
Engineering Data - FTXN-MV1 Series (R410A model)
MODEL
INDOOR UNIT
FTXN25MV1
FTXN35MV1
FTXN50MV1
INDOOR UNIT
CONTROL
AIR DISCHARGE
AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
OPERATION
LCD REMOTE CONTROL
AIR FLOW
TURBO
l/s / CFM
178 / 378
185 / 392
273 / 578
HIGH
l/s / CFM
163 / 345
169 / 358
250 / 529
MEDIUM
l/s / CFM
128 / 272
133 / 282
222 / 471
LOW
l/s / CFM
101 / 215
109 / 232
197 / 418
QUIET
l/s / CFM
78 / 165
177 / 374
SOUND PRESSURE LEVEL (T/H/M/L/Q)
dBA
41/40/34/29/21
42/41/34/30/22
44/40/38/35/32
UNIT DIMENSION
HEIGHT X WIDTH X DEPTH
mm
288 X800 X 206
310 X 1065 X 224
PACKING DIMENSION
HEIGHT X WIDTH X DEPTH
mm
344 X 874 X 274
386 X 1136 X 314
UNIT WEIGHT
kg
9
14
CONDENSATE DRAIN SIZE
mm
19.05
FAN
TYPE
CROSS FLOW
DRIVE
DIRECT
FAN MOTOR
TYPE
INDUCTION
BRUSHLESS
INDEX OF PROTECTION (IP)
IP44
IP20
INSULATION GRADE
CLASS E
RATED INPUT POWER
W
37
42
37
RATED RUNNING CURRENT
A
0.19
0.21
0.32
MOTOR OUTPUT
W
18
40
POLES
4
8
COIL
TUBE
MATERIAL
Seamless Inner Groove Copper
DIAMETER
mm
7
FIN
MATERIAL
ALUMINIUM (HYDROPHILIC FIN)
FACE AREA
m
2
0.18
0.29
ROW
2
AIR QUALITY
FILTER
TYPE
TITANIUM APATITE
QUANTITY
pc
2
CASING
COLOUR
WHITE
ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT).
COOLING
HEATING
INDOOR: 27°C DB / 19°C WB
INDOOR: 20°C DB
OUTDOOR: 35°C DB / 24°C WB
OUTDOOR: 8°C DB / 6°C WB
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
Engineering Data - FFQ-CXV1 Series (R410A model)
MODEL
INDOOR UNIT
FFQ25CXV1
FFQ35CXV1
FFQ50CXV1
OUTDOOR UNIT
RX25DGXV1
RX35DGXV1
RX50CGXV1
INDOOR UNIT
CONTROL
AIR DISCHARGE
4 WAY AUTOMATIC LOUVER (UP & DOWN)
OPERATION
WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROL
AIR FLOW
HIGH
l/s / CFM
189 / 400
193 / 410
212 / 450
MEDIUM
l/s / CFM
184 / 390
184 / 390
203 / 430
LOW
l/s / CFM
175 / 370
170 / 360
193 / 410
SOUND PRESSURE LEVEL (H/M/L)
dBA
44 / 41 / 36
45 / 42 / 38
47 / 46 / 44
UNIT DIMENSION
HEIGHT X WIDTH X DEPTH
mm
250 X 570 X 570
WITH PANEL
HEIGHT X WIDTH X DEPTH
mm
295 X 640 X 640
PACKING DIMENSION
HEIGHT X WIDTH X DEPTH
mm
317 X 630 X 630
PANEL
HEIGHT X WIDTH X DEPTH
mm
127 X 700 X 700
UNIT WEIGHT (UNIT + PANEL)
kg
16 + 2
16 + 2
CONDENSATE DRAIN SIZE
mm
19.1
FAN
TYPE
TURBO
DRIVE
DIRECT
FAN MOTOR
TYPE
INDUCTION
INDEX OF PROTECTION (IP)
IP20
INSULATION GRADE
CLASS B
RATED INPUT POWER
W
62
62
74
RATED RUNNING CURRENT
A
0.28
0.28
0.32
MOTOR OUTPUT
W
18
18
22
POLES
6
COIL
TUBE
MATERIAL
SEAMLESS INNER GROOVE COPPER
DIAMETER
mm
7.00
FIN
MATERIAL
ALUMINIUM (HYDROPHILIC FIN)
FACE AREA
m
2
0.25
ROW
2
AIR QUALITY
FILTER
TYPE
WASHABLE SARANET FILTER
QUANTITY
pc
1
CASING
COLOUR
WHITE
ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT).
COOLING
HEATING
INDOOR: 27°C DB / 19°C WB
INDOOR: 20°C DB
OUTDOOR: 35°C DB / 24°C WB
OUTDOOR: 7°C DB / 6°C WB
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
Summary of Contents for 2MX45BGXV1
Page 2: ......
Page 4: ...ii ...
Page 36: ...32 Wiring Diagram Indoor Unit Model FTXN25 35MV1 Indoor Unit Model FTXN50MV1 ...
Page 37: ...33 Wiring Diagram Indoor Unit Model FFQ25 35 50CXV1 Indoor Unit Model FDMQ25 35C2XV1 ...
Page 38: ...34 Wiring Diagram Indoor Unit Model FDMQ50CXV1 Indoor Unit Model FLQ35EXV1 ...
Page 39: ...35 Wiring Diagram Indoor Unit Model FLQ50EXV1 ...
Page 50: ......