SQLC-216-212
27
(3) Control input check
Check of control input
State of the control input is displayed on the screen.
『0FF (oFF)』
:Control input OFF
『ON (on)』 :Control input ON
(4) Communication output check
Check of communication output
Measurement (voltage, current) with no input, numeric data
of fixed communication output (0%, 50%, 100%, SEq) will
be able to reply.
Select the numeric data in the【+】
【-】
switch, and press
the 【SET】
switch, the measurement data of all measuring
elements have been changed.
Numerical data:0% (measurement data 0), 50%
(measurement data 5000) 100% (measurement data 10000),
SEq (sequence number)
Please use it, such as counter test of the host system.
With regard to the sequence number, please refer to the "SQLC-72L Communication Specifications".
(5) LCD check
Check of LCD
The LCD can be check.
Every time the【SET】
switch is pressed, display is
switched over.
(6) Software version check
Software version
Version of the software can be check.
Display on output
Output value
Software version