CPXD-350,500 SERVICE MANUAL
- 19 -
5. Correspondence for user needs expect for a standard (continued)
5.5 Changing anti-stick time
Anti-stick time is 0.3~0.5 sec. at the shipment but it
becomes usable to adjust time by R15 on C0056P.
Anti-stick time is changed by welding method, wire diameter
and current setting.
5.6 Changing anti-stick voltage
Anti-stick voltage is 15~18V at the shipment but it
becomes usable to adjust time by R16 on C0056P.
Anti-stick voltage is changed by welding method and wire
diameter.
5.7 Changing crater repetition period
Crater repetition period is 2 sec. at the shipment but it
becomes usable to adjust time by R18 on C0056P.
5.8 Using AC100V heater receptacle
Extra heating is necessary to use gas regulator with heater, turn S1 No.4 to “ON” when use
AC100V heater receptacle.
Turn S1 No.4 to “OFF” when not to use heater receptacle. An energy saving function is operating.
Function of S1 No.4
ON: MS, AC100V and fan keep “ON”
OFF: MS, AC100V turn off 5 seconds after the welding end and fan turn off 6 seconds after the
welding end.
Factory setting
CPXD-350: OFF
CPXD-500: ON
Shorter
Longer
Arti-stick time regulation
Longer
Shorter
Arti-stick voltage regulation
Crater repetition period regulation
sec.
sec.
sec.
sec.
sec.