6-27
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
4.
Turn the parameter adjustment knob, and change the setting value.
5.
Depress the F (Function) key for one second or more.
⇒
The setting of internal function completes, and the display returns to a normal state.
6.7.2 Detailed information on internal functions
This section explains the detailed information of internal functions in the order of function No.
6.7.2.1
F1: Standard/Extended cable mode
Sets the the welding control status for extended cables for the application of STANDARD mode. This
function is available when TRAVEL SPEED is set to "STANDARD" and WELDING METHOD is set to
"DC".
Extending the cables at the base metal side/torch side or power cables such as torch cables can cause
extraordinary volume of spatter. When this happens, turning this function ON (extended cable mode)
can improve the status.
•
"ON": Extended cable mode
Set to "ON" for the length of extension cable longer than 30 m. The LED of STANDARD starts flashing
when setting to "ON".
•
"OFF": Standard mode
T I P S
• In using the welding power source in the "HIGH" mode, the setting of this function is set to
"OFF" and cannot be changed.
6.7.2.2
F4: Auto/Semi-auto mode
In combining the welding power source with a robot or an automatic machine, set I/O (interface) of the
welding source according to the application.
For the settings "0" to "2", refer to the table below. The settings "3" and "4" are the modes specifically for
the use with OTC robots. For details, refer to the instruction manual of the robot controller.
⇒
The set value is activated as it is changed.
⇒
Pressing the F (Function) key enables to return the
display to the status described in step 1.
Parameter
Setting
0 (Semi-automatic)
1 (Automatic machine 1)
2 (Automatic machine 2)
Cancellation of operation
stop
After short-circuiting the pins
[3]-[4] operation stop
terminals on the external
connection terminal block
TM3, and turn the power on
again. (*4)
Short-circuit the operation stop terminal pins [3]-[4] on the
external connection terminal block TM3. (*4)
A
V
s
㸣
m/min.
sec.
JOB No.
Hz