7-5
Chapter 7
Administrator F
unctions
W
ELDING
R
ESULT
C
ONTROL
F
UNCTION
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
2.
With the parameter adjusting knob and the WELD MONITOR key, select the desired monitor No.
3.
Turn the parameter adjustment knob, and change the setting value.
4.
Press and hold the WELD MONITOR key for one second or more.
⇒
The changed data values are saved and the LED of WELD MONITOR key lights off.
⇒
When the set target is achieved or at the time of WARNING detection, an alarm will appear on the
left/right digital meters. (
-
Details of welding control items)
7.2.2
Details of welding control items
This section explains about details of the welding control items.
7.2.2.1
Number of welding point
The number of welding points is controlled according to the setting range.
•
P10 (Cumulative number of welding points)
The interval from the start of current flowing triggered by the torch switch ON to the stop of output
triggered by the torch switch OFF is regarded as one count (one welding point) and accumulated.
The setting range of count value is between 0 and 999. The count value will be cleared according to the
"P12" setting. (If continuous operation is enabled, the value will be cleared when exceeding 999 and return
to 0.)
•
P11 (Target value of welding points)
Select the target value of welding points in the range from 0 to 999. When the "P10" count value reaches
the number of welding points specified here, an alarm appears indicating that the target is achieved.
(
-
Alarm indication when target is achieved)
•
P12 (Operation at the time when the target value of welding points is achieved)
Select the operation from 0 to 5 for the time when the target specified for "P11" is achieved. The set values
and operations when the target is achieved are as below.
●
Turning the parameter adjusting knob will change
the tens place digit of monitor No. (Example: "P10" -
> "P20" -> "P30" -> "P40")
●
Pressing the WELD MONITOR key briefly will
change the ones place digit of monitor No. (Example:
"P10" -> "P11" -> "P12")
⇒
When an appropriate monitor No. is selected on the
left digital meter, the right digital meter will flash.
⇒
The set value is displayed on the right digital meter.
⇒
To select another monitor No., press the WELD
MONITOR key briefly and set the ones place digit to
"0" on the left digital meter, and perform the step 2.
A
V
r
㧑
+
WARNING
m/min.
sec.
JOB No.
WELD
MONITOR
Hz
A
V
r
㧑
WARNING
m/min.
sec.
JOB No.
Hz