S
ETTING
W
ELDING
JOB
W
ELDING
C
ONDITION
C
HAPTER
6
84
6.6 Setting Welding JOB
This section explains how to set the welding JOB (welding mode or welding parameters).
6.6.1
Welding mode setting
Available combination of the welding mode is listed in the table below.
Standard specification
WELDING
PROCESS
GAS (*1)
WIRE
MATERIALS
WIRE DIA. (mm)
Manual/Auto.
Penetration
adjustment
ARXIS WB-P403L
ARXIS WB-P503L
DC
CO
2
Fe
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual (*2)/Auto.
Enable
Fe (FCW)
1.2
1.2/1.6
Manual (*2)
Enable
CrNi (FCW)
1.2
1.2/1.6
Manual (*2)
Enable
MAG (18 % CO
2
)
(*1-1)
Fe
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual (*2)/Auto.
Enable
Fe (FCW)
1.2
1.2/1.6
Manual (*2)
Enable
CrNi (FCW)
1.2
1.2/1.6
Manual (*2)
Enable
MAG (10 % CO
2
)
(*1-2)
Fe
0.8/1.0/1.2
0.8/1.0/1.2
Manual (*2)/Auto.
Enable
MAG (2 % O
2
)
(*1-3)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual (*2)/Auto.
Enable
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual (*2)/Auto.
Enable
MAG (2.5 % CO
2
)
(*1-4)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual (*2)/Auto.
Enable
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual (*2)/Auto.
Enable
MIG (100 % Ar)
(*1-5)
Al/99
1.2/1.6
1.2/1.6
Manual (*2)
-
Al/Si
1.0/1.2
1.0/1.2
Manual (*2)
-
Al/Mg
1.0/1.2/1.6
1.0/1.2/1.6
Manual (*2)
-
Cu Si
0.8/1.0/1.2
0.8/1.0/1.2
Manual (*2)
-
Cu Al
0.8/1.0/1.2
0.8/1.0/1.2
Manual (*2)
-
DC LOW
SPATTER
(*3)
CO
2
Fe
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
MAG (18 % CO
2
)
(*1-1)
Fe
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
MAG (10 % CO
2
)
(*1-2)
Fe
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
MAG (2 % O
2
)
(*1-3)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
MAG (2.5 % CO
2
)
(*1-4)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
DC
PULSE
MAG (18 % CO
2
)
(*1-1)
Fe
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual/Auto.
Enable
Fe (FCW)
1.2
1.2
Manual/Auto.
Enable
CrNi (FCW)
1.2
1.2
Manual/Auto.
Enable
MAG (10 % CO
2
)
(*1-2)
Fe
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
Enable
MAG (2 % O
2
)
(*1-3)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual/Auto.
Enable
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
Enable
MAG (2.5 % CO
2
)
(*1-4)
CrNi
0.8/1.0/1.2
0.8/1.0/1.2/1.6
Manual/Auto.
Enable
Cr 18
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
Enable
MIG (100 % Ar)
(*1-5)
Al/99
1.2/1.6
1.2/1.6
Manual/Auto.
-
Al/Si
1.0/1.2
1.0/1.2
Manual/Auto.
-
Al/Mg
1.0/1.2/1.6
1.0/1.2/1.6
Manual/Auto.
-
CrNi
1.0/1.2
1.0/1.2
Manual/Auto.
Enable
Cr 18
1.0/1.2
1.0/1.2
Manual/Auto.
Enable
Cu Si
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
Cu Al
0.8/1.0/1.2
0.8/1.0/1.2
Manual/Auto.
-
INCONEL
0.9/1.2
0.9/1.2
Manual/Auto.
-
TITANIUM
1.0/1.2
1.0/1.2
Manual/Auto.
-
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...