Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
6.7.2.32 F45/F46/F47: Special 2T (effective/initial standard time setting/crater standard time
setting)
Incorporates start condition and crater condition in the "2T" sequence.
•
Setting the internal function F45 to [ON] enables to carry out the start welding/crater treatment set by F46/F47 even
in the welding of "2T" condition.
•
When this function is enabled, "special crater" is displayed in the HOME screen, enabling the internal functions F46
and F47.
•
To the internal function F46, set the time for initial welding in the range of 0.0 to 10.0 seconds. Set the value in the
range of 0.0 to 10.0 seconds.
•
To the internal function F47, set the crater treatment time in the range of 0.0 to 10.0 seconds. Set the value in the range
of 0.0 to 10.0 seconds.
T I P S
•
When the internal function F45 is set to [ON], automatically the setting of "special crater" is
selected, disabling other welding modes. (The 2T/4T menu does not work.)
•
Welding process at crater treatment is the same as that of main welding.
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding JOB memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding JOB with remote control) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal function F29 to F32 (External input terminal setting) is set to "5" (Loading welding
condition).
㻌
㻌
㻌
㻌
ON
OFF
Torch switch
Gas flow
Output voltage
Wire feeding speed
Welding current
Pre-flow
Post-flow
Anti-stick time
No-load voltage
Slow-down speed
Crater-fil
㼘
Main welding
Start current
Crater-fill current
Welding current
Start condition
Set the time by F46
(0.0 to 10.0 seconds)
Set the time by F47
(0.0 to 10.0 seconds)
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...