S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
117
Chapter 6
W
elding Condition
6.7.2.28 F39/F40: Output current gain adjustment
If there is difference between the current value indicated on the touch panel and the actual output current value, the
difference can be calibrated through adjustment of F39/F40.
The output current value that can be changed by F39 is [1], which is equivalent to 1 A. The value that can be changed by
F40 is about 0.01 A, which is equivalent to [0.01].
This function can be adjusted only in the "calibration mode". For details, refer to "7.7
NOTE
•
Do not carelessly change the setting of this function.
6.7.2.29 F41/F42: Output voltage gain adjustment
If there is difference between the voltage value indicated on the touch panel and the actual output voltage value, the
difference can be calibrated through adjustment of F41/F42. The output voltage value that can be changed by F41 is [0.1],
which is equivalent to about 0.01 V. The value that can be changed by F42 is about [0.01], which is equivalent to about
0.01 V. This function can be adjusted only in the "calibration mode". For details, refer to "7.7
NOTE
•
Do not carelessly change the setting of this function.
6.7.2.30 F43: CAN ID
When multiple welding power sources are connected with a PC monitoring system, set ID for CAN.
6.7.2.31 F44: Reading welding JOB with remote control
Sets whether to read the welding condition registered to the memory by the analog remote control (optional) or not. This
function is effective when the internal function F4 (Auto/Semi-auto mode) is set to "0".
•
[ON]: reads the welding condition by the analog remote control (optional)
–
Setting the welding current setting knob on the analog remote control to 1-10 of the scale can read out
the conditions stored to the JOB No. 1-10.
–
By the welding voltage setting knob, fine adjustment of the welding voltage of the condition read out
is available. (% adjustment)
Adjust the voltage value based on the center of welding voltage setting knob. To increase the welding
voltage, turn the knob clockwise and to reduce the welding voltage, turn the knob counterclockwise.
The fine adjustment range for welding voltage is up to ±20 %.
•
[OFF]: disables the function.
•
In the following cases, this function cannot be used:
–
Welding JOB are not registered to the memory;
–
Analog remote control (optional) is not connected to the welding power source;
–
Internal function F11 (Fine adjustment of welding JOB memory) is set to "1" to "30" (enabled);
–
Internal function F45 (Special 2T) is set to "ON" (enabled);
Example:
The right figure shows an example when the JOB No. "3" is read out and the
welding voltage is the condition stored on the memory (no fine
adjustment).
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...