Chapter 6
W
elding Condition
6.7.2
Detailed information on internal functions
This section explains the detailed information of internal functions in the order of function No.
6.7.2.1
F1: Standard/Extended cable mode
Sets the welding control status for extended cables for the application of Manual mode. This function is available when
Manual/Auto. is set to "Manual" and WELDING PROCESS is set to "DC".
Extending the cables at the base metal side/torch side or power cables such as torch cables can cause extraordinary volume
of spatter. When this happens, turning this function ON (extended cable mode) can improve the status.
•
[ON]: Extended cable mode
Set to "ON" for the length of extension cable longer than 30 m. Set to "ON", "DC (extended)" will be displayed at the
welding process menu in HOME screen.
•
[OFF]: Standard cable mode
T I P S
•
In using the welding power source in the "Auto." mode, the setting of this function is set to
"OFF" and cannot be changed.
•
When the status is not improved even by setting of this function to "ON", combined use of
the voltage detection cable is recommended.
•
When using the voltage detection cable, set the internal function F38 (Arc voltage detection
switching) to "1". (
-
F38: Arc voltage detection switching)
6.7.2.2
F2: Function Selection with the Remote
Sets the functions to be allocated to the switching knob of the analog remote control.
The selectable functions are "1" through "6" as shown in the below table. No function will be allocated if set at "0".
6.7.2.3
F4: Auto/Semi-auto mode
In combining the welding power source with a robot or an automatic machine, set I/O (interface) of the welding source
according to the application.
For the settings "0" to "2", refer to the table below. The settings "3" and "4" are the modes specifically for the use with OTC
robots. For details, refer to the instruction manual of the robot controller.
Setting
Function
0
No function
1
Crater setting
(
)
2
Gas check
(
)
3
Constant penetration
(
4
Tack start
(
6.7.2.39 F54 Tack start process
)
5
Reading welding JOB with remote control
(
Reading welding JOB with remote control
)
6
Welding JOB
(
Parameter
Setting
0 (Semi-automatic)
1 (Automatic machine 1)
2 (Automatic machine 2)
Cancellation of operation stop
After short-circuiting the pins [3]-
[4] (operation stop terminals) on
the external connection terminal
block TM3, and turn the power on
again. (*4)
Short-circuit the operation stop terminal pins [3]-[4] on the external
connection terminal block TM3. (*4)
Stuck wire removal voltage (*1) Voltage is not output.
Voltage is output for approx. 0.2 seconds after completion of anti-stick
process.
Welding current/voltage setting
Set by operation panel or remote
control.
Set by external command voltage
(*2)
Set by operation panel or remote
control.
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...