background image

DAIHAN-Sci.com or 

ALL 

for

 

LAB.com

 Shopping Mall

 

DAIHAN Scientific, Ultra Low Temperature Smart Freezer                                                                                              3/58 

 

Table of Contents 

 

                                                                         

Page

 

1. General 

      1.1 Precautions Before Use ............................................................................    4 

      1.2 Product Introduction ................................................................................    5 

      1.3 Product Configuration ..............................................................................    6 

2. Installation   

      2.1 Product Installation ...................................................................................    7 

      2.2 Installation of WiRe

TM

 App & Web Service ...................................................    8 

2.3 Product Specifications    .............................................................................. 15 

3. Product Usage 

      3.1 Product Usage .........................................................................................    16 

      3.2 Names of Each Part .................................................................................    20 

      3.3 Usage Instructions ...................................................................................    22 

4. Products Management Methods 

      4.1 Accessories .............................................................................................    35 

      4.2 Maintenance and Management .................................................................    36 

      4.3 Troubleshooting .......................................................................................    37 

5. Product Assurance 

      5.1 Quality Assurance ....................................................................................    38 

 

Summary of Contents for UniFreez U80

Page 1: ...P Certified Only DuoFreez U500 Model PL Insurance Product Liability Insurance Validation IQ OQ Service User Manual Version 2 2 2 written for UniFreezTM U80 models UniFreezTM U80 Ultra Low Temperature...

Page 2: ...DAIHAN Sci com or ALL forLAB com Shopping Mall DAIHAN Scientific Ultra Low Temperature Smart Freezer 2 58...

Page 3: ...on 5 1 3 Product Configuration 6 2 Installation 2 1 Product Installation 7 2 2 Installation of WiReTM App Web Service 8 2 3 Product Specifications 15 3 Product Usage 3 1 Product Usage 16 3 2 Names of...

Page 4: ...ct after being well acquainted with the meaning Warning Failure to follow the instructions may result in injury Caution Failure to follow the instructions may result in product failure Proximity Cauti...

Page 5: ...an prevent cold air leakage and the intrusion of the outside temperature and maximize the insulation effect because of the rigid polyurethane foam insulation and the insulation for inside the door 3 l...

Page 6: ...n Manual Models UniFreezTM U300 Ultra Low Temperature Freezer Upright type 86 308Liter UniFreezTM U400 Ultra Low Temperature Freezer Upright type 86 393Liter UniFreezTM U500 Ultra Low Temperature Free...

Page 7: ...inside of the body 7 This product was manufactured for normal operation at a rated voltage so please check the voltage status before installing the product 8 When installing and using the product ple...

Page 8: ...by finding the wireless LAN among the components of the product This description is for the installation method for users who want to use WiReTM App Web Service Only matters that should be installed w...

Page 9: ...ght of all displays for each menu to go back to previous display 1 System Settings 1 Current Time Set The present time is set to input correct test time of user Touch the box displaying time and date...

Page 10: ...on the right prepared for the Use 24 hour format must be checked for the correct operation of the product and users should never change it After completing the setting of the product push the return b...

Page 11: ...d on top right of the display to go back to previous page 2 WiRe Settings Slide the WiRe Mode button to the right to connect to the WiReTM Service This will only be enabled by the stabilized Wi Fi con...

Page 12: ...to be registered in this product When the user is logged in with the registered ID from the Mobile App then the list of devices already registered will be appearing 2 Deletion of Users Registered use...

Page 13: ...haracters will encounter the pop up message showing the disability of Password setting Once the ID Password and Name are set in the list then they cannot be modified thereafter 4 Setting of Authority...

Page 14: ...the message showing the disability to invoke the information of registered users may come from the unstable Wi Fi connection Check the status of Wi Fi connection and then reenter into the menu of WiR...

Page 15: ...en TFT LCD Shelves Included 1 Stainless Steel Shelf Max Q ty of Racks 4pcs of 12 3x4 Placed Rack RFU8 Material Internal Stainless Steel 304 External Powder Coated Steel Plate Inner Door Powder Coated...

Page 16: ...rack should be wiped with a soft cloth and then used after mounting it before connecting the power of this product Please put the sample into the instrument after the instrument starts to operate and...

Page 17: ...ut your hands into the mechanical room air outlet or inlet Since the fan is operating at high speed it may cause burns or injury Please do not hang on the door It may cause personal injury or short ci...

Page 18: ...e move it so that the power cord and the product are not damaged after disconnecting the power plug from the electrical outlet It may cause electrical shock or ignition due to damage to the cord If re...

Page 19: ...nion s Waste Electrical Electronic Equipment WEEE Directive 2002 96 EC l When reinstall products When moving this product please consult with a DAIHAN Scientific Inc Service Center or Nationwide Agent...

Page 20: ...open the Door Door Handle Door open and close Block Condenser Condenser without Pin and Filter Main Power Switch Power ON OFF Circuit Breaker Leakage Breaker RS232C Interface Serial Interface for Rem...

Page 21: ...CHART Monitor the operating status by chart SETTINGS Set up and adjust various functions of the instrument Error If the error of the instrument occurs perform the alarm function WiFi status It shows...

Page 22: ...product and the alarm and LCO2 spraying can be operated when there is a problem in the power supply such as a power outage Please start operation after at least one minute when you turn ON the power s...

Page 23: ...button located on top right of all display to go back to previous display The SETTING menu will be deactivated during the operation of the product Push the STOP button located on top right of the disp...

Page 24: ...in the Chart can be set Users can select the one among the options of 30 seconds 1 minute and 2 minutes 2 Temp Failure Condition The value of temperature deviation from the target temperature can be...

Page 25: ...ion System Settings 1 Buzzer The alarm of error can be set as On or as Off 2 Touch Sound The sound of Touch Button can be set as ON or as OFF 3 Data Initialization The stored data of Operation Setting...

Page 26: ...the product can be locked to prevent unauthorized operation of the controller for particular settings of the product Slide the button to the right to activate the lock 2 Password Change The password s...

Page 27: ...Chambers The number of Chambers created by the shelves installed inside of the product is inputted Max 5 2 Racks Boxes The number of Racks and Boxes therein that are to be stored in each Chamber are...

Page 28: ...e ECO mode is deactivated in the product of UniFreezTM model 2 Compressor Switching Period Here the period of alternate running of the two compressors can be set The set number implies the number of d...

Page 29: ...he data into the USB When the inserted USB is not recognized then it will be notified through the pop up message Press the button OK and then separate the USB from the port Insert the USB into the por...

Page 30: ...e graph The part of the display of details is the vertical line of orange color that is indicated as a straight line on the whole graph 3 3 4 OFFSET When the two thermometers that are displayed in the...

Page 31: ...Users may write the name of selected Rack or information thereof Click the Box in the right picture representing the position of the Box to input information thereof Please follow the sequence of the...

Page 32: ...ing the button Export that initiates the overwriting execution of current information Be sure to back up previous information before doing every Export The folder created in the USB by the Export will...

Page 33: ...mport Be sure to check whether the files created in the PC have names as they were sequentially assigned Otherwise the Import would not be enabled Ex If there are files in the PC with the names assign...

Page 34: ...mage to valuable samples can be prevented by LCO2 This operation is activated when reaching the setting temperature and if the temperature becomes higher than the setting temperature LCO2 is automatic...

Page 35: ...140 X d430 X h220mm for SWUF 80 without boxes C11 001 Hard Board Box with Hard Board Divider 81 Holes 127 X 127 X h52mm C11 002 Hard Board Box with PolyPropylene Divider 81 Holes 127 X 127 X h52mm DH...

Page 36: ...vation samples from the instrument and wipe it off with a dry cloth and dry it while leaving the door open after washing it out with warm water and some neutral detergent 6 Please apply the polish for...

Page 37: ...gh temperature exists close to the freezer Confirm that the ventilation around the instrument is good The same abnormal status as above does not exist but if the temperature does not fall well please...

Page 38: ...out all functions before shipment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 T...

Reviews: