![Dahua VTO7521G Quick Start Manual Download Page 17](http://html1.mh-extra.com/html/dahua/vto7521g/vto7521g_quick-start-manual_500228017.webp)
Configuration
12
TCP/IP information
Figure 5-5
Enter network parameters you planned, and then click
Save
.
Step 2
The VTO will restart.
Make IP address of your PC and VTO IP are in the same network segment.
5.3.4 Selecting SIP Servers
The Session Initiation Protocol (SIP) is used for signaling and controlling multimedia
communication sessions in applications of voice and video calls. A SIP server is an application
provides information or direction to a user agent.
When this VTO or another VTO works as SIP server, select
VTO
from the
Server Type
drop-down list. It applies to a scenario where there is only one building.
When the platform (Express/DSS) works as SIP server, select
Express/DSS
from the
Server Type
drop-down list. It applies to a scenario where there are multiple buildings or
multiple units.
Log in to the web page.
Step 1
On the homepage, select
Local Setting > Basic
.
Step 2
The
Device Properties
interface is displayed. See Figure 5-6.
Device properties
Figure 5-6
1) Select
TCP/IP
from the
System Type
drop-down list.
Default system type is analogue system and shall be changed to TCP/IP.
Otherwise, it will fail to connect VTH.