2
Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
VTNS1060A
Switch
VTO2202F-P
Module
802.3af PoE
24v PoE
Tamper Switch
Sounds an alarm in the event that the VTO unit is tampered with
Network Connection
Connect the supplied RJ45 adapter cable to this port
+12v
Used when not powering the VTO via PoE, connect the 12v or 24v DC positive supply to this
terminal
GND
Ground connection for 12v DC negative supply and other inputs
12v Out
DC 12v continuous output for auxiliary device (100mA max)
Door Button
Input to connect a switch such as a push button for releasing the door lock
Door FB
Input for door contact to check if the door is closed before engaging lock
Door NO/NC/COM
Relay output used when unlocking door
RS485 A/B
RS485 Bus for connecting secondary lock controller DEE1010B
Main VTH Monitor
VTH Passive PoE Monitor
Camera Module
When confi guring a home VDP system, all devices should fi rst be connected together. Usually, this is done by connecting both the
camera unit (VTO) and monitor unit (VTH) to the VTNS1060A PoE switch.
The VTNS1060A is a 24v passive PoE unit, this is a different type of PoE than that seen on conventional IP devices. As such, both the
VTO2000A and VTH1550CH can only be used with 24v passive PoE or by connecting a 12/24v DC power supply to the power input
terminals on the units.
Example 1
Example 2
HOME SYSTEM CONFIGURATION
VTO CONNECTIONS
PoE
Switch
Ethernet Link
VTNS1060A
Switch
802.3af PoE
24v PoE
PoE
Switch
Ethernet Link
Tamper
Switch
NET
Network
Connection
Inputs &
Outputs
GND
ALARM_COM
DOOR_FB
DOOR BUTT
ON
ALARM_ON
GND
DOOR_NC DOOR_COM DOOR_NO
12V_OUT
RS485_B RS485_A
EOC1(+12) EOC1(GND)