background image

User Port 

Power supply, connect to lock, door sensor and 

unlock button.   

Project Port 

Reserved for project staff use.   

 

2.4  Electric Control Lock and Electromagnetic Lock 

2.4.1 Electric Control Lock 

When VTO connects to electric control lock, it means that the positive end of electronic 

control lock connects to NO of VTO (user port 10) while its negative end connects to COM 

of VTO (user port 12).   

When VTO connects to unlock button, one end of unlock button connects to BUTTON of 

VTO (user port 7) while the other end connects to CND of VTO (user port 9). See Figure 

2- 9. 

 

 

Figure 2- 9 

 

 

2.4.2 Electromagnetic Lock 

When  VTO  connects  to  electromagnetic  lock,  it  means  that  the  positive  end  of 

electromagnetic lock connects to NC of VTO (user port 11) while its negative end connects 

to COM of VTO (user port 12).   

When  VTO  connects  to  door  sensor  in  electromagnetic  lock,  one  end  of  door  sensor 

connects to FEEDBACK of VTO (user port 8) while the other end connects to GND of VTO 

(user port 9). See Figure 2- 10. 

Summary of Contents for VTO2000A Series

Page 1: ...1 VTO2000A Series User s Manual V1 1 0...

Page 2: ...p Call Scene 4 2 Install VTO 5 2 1 Direct Installation 5 2 1 1 Screw 5 2 1 2 Dimension 5 2 1 3 Installation Step 6 2 2 Embedded in Wall 8 2 2 1 Screw 8 2 2 2 Dimension 9 2 2 3 Installation Step 9 2 3...

Page 3: ...tatus Statistics 12 4 4 1 VTH Status 12 4 5 Logout 12 5 Basic Function Introduction 13 5 1 Call Function 13 5 1 1 Call Resident 13 5 1 2 Group Call 13 5 2 Monitor 16 5 3 Unlock Function 16 5 4 Compens...

Page 4: ...not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not place any object on the...

Page 5: ...lock via IC card Button Type Lock Control Module VTO2000A Metal Silver N A Mechanical key Built in 1 2 Structure 1 2 1 Structure Before installation please make you sure know the dimensions of device...

Page 6: ...orresponding door region 3 Compensation Light Light compensation will automatically turn on during monitoring calling or connecting status if there is no enough light in environment 4 Speaker Audio ou...

Page 7: ...k Port Via convertor connect network cable RJ45 crystal head 4 User Port Connect to lock door sensor feedback and unlock button 5 Project Port Reserved for project staff use 1 3 Networking Scene Here...

Page 8: ...itor press Call on VTO multiple VTH will ring at the same time The resident can anwer hang up or unlock door from any of the VTHs Note VTH has main VTH host and sub VTH extension One host can have up...

Page 9: ...ng to the following specifications and install by following this guide Component Name Illustration Quantity M3 6 Hex slot pan head tail machine screws galvanizing white 4 M3 8 Cross recessed countersu...

Page 10: ...s recessed countersunk head tail tapping screws galvanizing white and fix metal bracket on wall See Figure 2 2 Step 2 Align the device on metal bracket according to screw hole Fasten screw M3 8 Cross...

Page 11: ...Figure 2 2...

Page 12: ...y bag according to the following specifications and install by following this guide Component Illustration Quantity M3 6 Hex slot pan head tail machine screws galvanizing white 4 M3 8 Cross recessed c...

Page 13: ...tion Step Step 1 Dig a hole on wall its dimension is 117 128 80 mm See Figure 2 5 Step 2 Embed metal bracket into wall until its four peaks lean against the wall See Figure 2 6 Step 3 Align the device...

Page 14: ...Figure 2 5 Figure 2 6...

Page 15: ...Figure 2 7 2 3 Wiring See Figure 2 8 Figure 2 8 No Component Name Note 1 Network Port Via convertor connect to network cable RJ45 crystal head...

Page 16: ...2 When VTO connects to unlock button one end of unlock button connects to BUTTON of VTO user port 7 while the other end connects to CND of VTO user port 9 See Figure 2 9 Figure 2 9 2 4 2Electromagneti...

Page 17: ...Figure 2 10...

Page 18: ...ers working status Name plate area indicator turns white Step 2 Via direction connection of Ethernet cable to connect device and PC set PC IP address to be in the same network segment with VTO IP addr...

Page 19: ...rding to the following steps Step 1 In Internet Explorer input IP address of the VTO enter username and password click Login to login WEB Note Default IP address of VTO is 192 168 1 110 Default userna...

Page 20: ...Step 3 In System Time tab click on Sync PC to make VTO time the same with PC Step 4 Select System Config Network Config set VTO IP Subnet Mask and Default Gateway See...

Page 21: ...gure 4 1 Parameter Note Sensor Set compensation light threshold Device Type Display device type Reboot Date On the set date device will automatically reboot Version Info Display device version info De...

Page 22: ...emains unlocked over set door sensor check time it alarms Check Door Sensor Signal Before Lock Default Only restore A C Manager page to default settings 4 1 1 3 Talk Manager The device supports talk m...

Page 23: ...eck card no VTH info and click so you can back up card no and VTH info Restore Backup Check card no VTH info and click to recover card no and VTH info Export Export config file Config backup Import Im...

Page 24: ...ital indoor station For example to add digital VTH Step 1 In tab select System Config Indoor Manager Digital VTH Manager Step 2 Click Step 3 Fill in digital VTH basic info See Figure 4 6 Figure 4 6 No...

Page 25: ...ou modify analog VTH you can only modify name nickname distributor address and distributor port Click delete digital VTH 4 1 4 Network Config 4 1 4 1 TCP IP You can set local IP network parameter Step...

Page 26: ...nd etc User can login FTP server to view and get photo or image You can go to System Config Network FTP to set local FTP network parameter See Figure 4 9 Figure 4 9 4 1 4 3 P2P You can go to System Co...

Page 27: ...ess Adjust video brightness recommended value is 40 60 range is 0 100 Contrast Adjust video image contrast recommended value is 40 60 range is 0 100 Saturation Adjust color saturation recommended valu...

Page 28: ...and view user info in User Manage interface Current system supports two types of user Admin has higher right who can view edit delete configured right User only can view system config 4 1 6 1 Add Use...

Page 29: ...cannot modify note information or delete it Step 1 Select System Config User Manager enter User Manager interface See Figure 4 14 Figure 4 14 Step 2 Click to delet user Step 3 Click to modofy user in...

Page 30: ...modify all IPC info Step 1 Select System Config IPC info Step 2 Click Step 3 Modify IPC info See Figure 4 16 Figure 4 16 Step 4 Click 4 3 Info Search You can search and export VTP unlock call and alar...

Page 31: ...cord You can search VTO alarm in Alarm Record interface and it stores up to 1024 records Figure 4 18 4 3 3 Unlock Record You can search VTO unlock records in Unlock Record interface and it stores up t...

Page 32: ...VTH is disconnected you cannot call monitor or talk Online Connection between VTO and VTH is ready you can call monitor and talk Monitor Status Unmom VTH is not monitoring Onmom VTH is monitoring Fig...

Page 33: ...1 2 Group Call Group call is mainly used for one VTO Press Call button on VTO to call multiple VTH at the same time A resident can answer hang up and unlock on any one unit of VTH VTH consists of mast...

Page 34: ...enter logout interface reboot VTO See Figure 5 2 Figure 5 2 Configure Main VTH Step 1 In VTH screen press System Config and press Project settings input password default is 002236 and enter Project s...

Page 35: ...nfig and press project settings input password default is 002236 and enter project settings interface Step 2 Press local info Press master and it changes to extension Step 3 Set room no fill in local...

Page 36: ...called calling or monitoring center can remotely unlock door VTO will return to standby interface after call ends or countdown stops Unlock by VTH When VTH is called calling or monitoring VTH can rem...

Page 37: ...rd Info If you encounter abnormality with card info or accidently restore default settings you can restore card info with this function Restore VTH Info If VTH info is mistakenly changed you can resto...

Page 38: ...error please check the cables of the device and its extension 5 Q Volume is too low A Adjust the VTO and VTH call volume 6 Q The device does not boot up A Check the power supply between VTH and VTO 7...

Page 39: ...sion Support Audio Input Omnidirectional Mic Output Built in speaker Talk Support bidirectional talk Operation Mode Input Single key input Door Lock Status Check Support optional Network Ethernet 10M...

Page 40: ...te Please do not let LN be over 100m Appendix 2 2 Power Extension Line Specification The wiring length between VTO and adaptor is LC so reasonable specification of extnsion line is Extension Line Spec...

Page 41: ...here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer...

Reviews: