Local Setting 11
Parameter
Description
Menace Password
Under any of these two situations you can use menace password.
By default, the menace password is entering the public unlock
password reversed.
You can configure any number as needed.
Once the duress password is used
When using VTO as SIP server, there will be an alarm record
at
Log Management > Alarm
.
When using platform as SIP server, you can connect alarm
output device to get alarm notice.
Menace Password
Confirm
Click
Save
.
Step 3
4.3.2 RS485
This section introduces the access control configuration of RS-485 devices, including lock and
lift control.
On the main interface (Figure 3-1), select
Local Setting > Access Control > RS485
.
Step 1
The
RS485
interface is displayed. See Figure 4-4.
RS485
Figure 4-4
Configure parameters, and you can select
Lock
or
Lift Control
in the
Interface Type
Step 2
list. For the detailed description, see Table 4-4.
Table 4-4 RS-485 access control parameter description
Parameter
Description
Lock
Unlock
Responding
Interval
The time interval to unlock again after the previous unlock,
and the unit is second.
Unlock Period
The time amount for which the lock stays open after unlock,
and the unit is second.
Second Unlock
Command
You can connect a third-party phone such as SIP phone to
your VTO, and use the command to open the door remotely.
Second Lock
You can connect one more door to RS-485 device.
If you select the
Enable
check box, then the second lock
will be opened by default when pressing unlock button,
swiping access card or using unlock password.
If you do not select the
Enable
check box, then the first
lock will be opened by default when pressing unlock
button, swiping access card or using unlock password.
Lift
Control
Lift Control
Protocol
Select the protocol as needed to enable the lift control
function, and then you can configure the floors that lift users