Integrated Mount Tester

User Manual

V1.0

Summary of Contents for PFM906

Page 1: ...Integrated Mount Tester User Manual V1 0 ...

Page 2: ... first read the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will be charged for repair service If there is any question or problem while using the Integrated Mount Tester or damages occurred on the product please contact our technical Department ...

Page 3: ...n 19 3 2 1 IP camera connection 19 3 2 2 Analog camera connection 20 3 2 3 HD Coaxial camera connection 20 3 2 4 HDMI IN 21 3 3 OSD menu 22 3 3 1 Lite mode Normal mode 22 3 3 2 Drop down Menu 25 3 3 3 Short cut menu 26 3 3 4 Screen capture 27 3 3 5 TesterPlay 27 3 3 6 Rapid video 29 3 3 7 IP discovery 30 3 3 8 Rapid ONVIF test 31 3 3 9 IP camera test 43 3 3 10 HDMI IN 46 3 3 11 Video monitor test ...

Page 4: ...IP Discovery 79 3 3 19 PoE power DC12V 2A and DC 5V 2A USB power output 79 3 3 20 Cable test 80 3 3 21 RJ45 cable TDR test 81 3 3 22 Cable search 84 3 3 23 TDR cable test 85 3 3 24 PoE Voltage test 88 3 3 25 12V power input test 89 3 3 26 Digital Multi meter 89 3 3 27 Optical power meter 97 3 3 28 Visual Fault Locator 98 3 3 29 Audio record 100 3 3 30 Data monitor 100 3 3 31 Audio player 101 3 3 3...

Page 5: ... 41 System setting 113 3 3 42 File explorer 117 3 3 43 Theme 118 3 4 Audio test 121 3 5 HDMI output 121 3 6 PoE power output 122 3 7 DC12V 2A power output 122 4 Specifications 124 4 1 General specifications 124 4 2 Multi meter specifications 127 4 3 Optical power meter specifications 129 4 4 Visual fault locator specifications 130 ...

Page 6: ...nce no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument should not be used under the environment with strong electromagnetic interference Don t touch the tester with wet hands or waterish things Don t use the detergent to clean and the dry cloth is suggested to use If the dirt is not easy to remove ...

Page 7: ...ess the capacitor to be measured has been discharged fully Never measure any of resistance capacitance diode or continuity measurements on live circuits Visual laser sources When you turn on visual laser sources please don t stare at it or will damage to eyes When not using it please turn it off and cover the protective cap ...

Page 8: ... DC 12V 2A power output and much more Its portability user friendly design and many other functions make the tester an essential tool for all installers or technicians 2 2 Features New 7 inch touch screen CCTV tester with retina display 1920 1200 resolution H 264 4K video display via mainstream In HDMI IN mode It can converter test from analog to digital with dual test window IP HDMI IN or Analog ...

Page 9: ...amera quickly auto log in and display image from the camera activate camera Hik test tool app is design for activating and debugging Hikvision camera can auto identify unactivated hikvision camera also can display image from the Hikvision camera DH test tool app is design for Dahua Camera test and modify IP user name and password parameters etc ONVIF camera test support 2592x1520 It is used unique...

Page 10: ...eakage Optical power meter test fiber loss and value Digital Multi meter DC and AC voltage measurement Resistance measurement Continuity test Diode measurements Capacitance measurement PEAK video signal level SYNC signal level Color burst chroma level measurement test video signal attenuation Cable tracer by sending the audio signal enables the blue cable tracer tester to find the connected cable ...

Page 11: ...attery charge indicator Lithium Ion Polymer Battery can last 10 hours for normal use after charging for 5 6 hours 2 3 Function 2 3 1 4K mainstream test With the new hardware decoding display the image from the 4 K camera 2 3 2 Retina display and touch screen operation 7 inch touch screen cctv tester with retina display 1920 1200 resolution 2 3 3 Intelligent interface You can select Lite mode or No...

Page 12: ...t from analog to digital with dual test window IP CVBS 2 3 10 Dual test window IP HDMI IN or Analog HDMI IN 2 3 11 It can converter test from analog to digital with dual test window IP CVBS 2 3 12 Theme Set function apps background you can select 4 different colors at the same time Set the desktop and application interface background you can choose pure colors or custom pictures You also can chang...

Page 13: ...P settings Wi Fi HDMI IN CVBS Video OUT LAN Brightness settings etc 2 3 20 CVBS loop test TV out testing app it can send and receive color bar generator through the tester s video out and video in 2 3 21 IP discovery IP discovery do not need to know the first two digits of camera s IP address it can auto scan the whole network segment IP and auto modify tester s IP address 2 3 22 Rapid ONVIF Rapid...

Page 14: ...justable 2 3 27 Video level meter Perform NTSC and PAL video amplitude signal measurements for PEAK to PEAK SYNC levels and COLOR BURST chroma level Video signal PEAK to PEAK level For NTSC format the video signal level is 140 15IRE For PAL format the video signal level is 1000 200mV If the level is too low it will cause the image to lose quality and limit the distance it will travel over cable If...

Page 15: ...log cameras For PTZ testing setup the controlling parameters from the meter to match those of the camera e g PTZ protocol PELCO D etc communication port RS 485 etc baud rate PTZ camera ID and pan tilt speed 2 3 29 DC 12V 2A power output port and DC 5V 2A USB power port The unit can power a camera with its DC 12V 2A power output Also included is a built in DC 5V 2A power output port used to charge ...

Page 16: ...em color bar video generator and pure blue black colorful imagines by receiving the video color bar to test the video channel whether transmit normally And judge whether the color is different because of the transmission loss or interference it suitable for video transmission of the field tests such as optical video transmitter and receiver video cable etc The new function color bar can test the i...

Page 17: ...nt Continuity test Diode measurements Capacitance measurement Auto Manual measuring range switching relative value measurement and locking It is easy operation and professionally accurate 2 3 44 Visual fault locator Visual Fault Locator with 650nm wavelength can emit red laser sources to test multi mode and single mode fiber s bending and breakage and Continuous light emitting and 1Hz 2Hz modulati...

Page 18: ...t 1080P 50 60 FPS digital camera image test and video image zoom record snapshot photo viewer and video playback 2 3 50 CVI camera test Support 2560x1440P 25F 30F 4xzoom video record and playback coaxial PTZ control and call camera OSD menu 2 3 51 TVI camera test Support 2560x1944P 12 5FPS 4xzoom video record and playback coaxial PTZ control and call camera OSD menu 2 3 52 AHD camera test Support ...

Page 19: ...ing the settings 2 3 58 FTP Server Start the tester s Wi Fi or connect the tester s LAN port to the network Once the tester is online start its FTP Server and directly access files from the tester This also allows for the user to upgrade the tester firmware 2 4 Packing list 1 Tester 2 Adaptor DC12V 2A 3 Network cable tester 4 Polymer lithium ion battery 7 4V DC 5000mAh 5 BNC cable 6 RS485 cable 7 ...

Page 20: ...earby 6 TELE zoom in the image 7 WIDE zoom out the image 8 Open set Confirm the setting of parameters open or enlarge the aperture 9 10 Upward set function or add parameter Tilt the PTZ upward 11 Rightward select the parameter whose value will be changed Add the value of the parameter Pan the PTZ right 12 Leftward select the parameter whose value will be changed 13 Downward set function or reduce ...

Page 21: ...eing charged As the charging is complete the indicator turns off automatically 18 The RS485 data transmission indicator it lights red while the data is being transmitted 19 The data received indicator it lights red while the data is being received 20 The power indicator it lights green while the tester is powered on by the adapter Top interface Bottom interface 21 TDR cable test interface 22 SDI i...

Page 22: ...to test PoE or non PoE IP camera 29 PSE power sourcing equipment Tests PoE voltage 30 DC 12V 2A power output for provisional DC power supply 31 LED lamp 32 Visible red laser source emits Interface 33 Power 34 DC 12V 2A charging interface 35 Audio input 36 Audio output and earphone interface 37 USB 5V 2A power output used only for power not data 38 UTP cable port UTP cable tester port Cable tracer ...

Page 23: ... When the battery icon is full or the charge indicator turns off automatically indicate the battery charging is completed Notice When the Charge Indicator turns off the battery is approximately 90 charged The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery Notice Press the key several seconds to restore the default settings when the ...

Page 24: ...en connect the IP camera to the tester s LAN port The tester will supply PoE Power for the IP camera Click on the icon labeled POE to turn the PoE Power off or on 2 If use the tester s menu to turn off the tester s PoE power supply the PoE switch and the power sourcing equipment are allowed to connect to the tester s PSE port and the PoE power will be supplied to the IP camera by the tester s LAN ...

Page 25: ...ical video transmitter and receiver the image display on the tester and monitor 3 Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface Note positive and negative connection of the cable 3 2 3 HD Coaxial camera connection SDI EX SDI CVI TVI AHD camera are classified as HD coaxial cameras Hereby the following instruction of how to connect SDI camera to the tester...

Page 26: ...only come with SDI input interface There is no SDI output interface 2 Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface Note positive and negative connection of the cable 3 2 4 HDMI IN DVR or other device s HDMI in port connect to tester s HDMI in port the meter will display input image ...

Page 27: ...ey to enter sleep mode press it again to test If tester works abnormally and cannot be turned off Press the key several seconds to turn off the tester reset 3 3 1 Lite mode Normal mode Lite mode You can easy find corresponding apps In Lite mode Press the icon several seconds can move the icon to other apps ...

Page 28: ...icons sequence Normal mode Tap the screen and slide left or right to change menu In normal mode press icon several seconds go screen management status Change icons sequence and move it to common tools bar You can move the icon to any pages self define the number of icons in any page Make interface sample and individuality ...

Page 29: ...ew named folder Press the folder several seconds to change the folder name you can move the icon out of folder the folder will be auto deleted until move out all icons Select Icons to enter if quit please click Click SD card install or remove SD card NOTICE SD card is not default accessory please purchase separately if necessary ...

Page 30: ...can converter test from analog to digital with dual test window IP HDMI IN or Analog HDMI IN CVBS Click icon CVBS to enter you can test IP and analog camera at the same time Video OUT Click Video OUT to enter floating window connecting the BNC cable to tester and appears analog video monitor interface it can test circuit and BNC cable whether normal LAN display network port or WIFI connection real...

Page 31: ...on or off the tester PoE power app WLAN Turn on WLAN net and displays current WLAN status 3 3 3 Short cut menu You can call shortcut menu by press tester s menu key you can self define shortcut menu Press the key you can turn on it and switch functions then press to enter app tap other area on the screen to exit the menu ...

Page 32: ...can capture screen interface and save it in any time 3 3 5 TesterPlay Mobile screen projection Only for android version The meter creates WIFI hotspot connect mobile phone to the tester s WIFI hotspot or the tester and mobile phone connect to the same Wi fi network Tap icon then select TesterPlay app to enter the meter generates two dimensional code Please use mobile phone scan it then download an...

Page 33: ...the VLC player Media Open Network Streaming and input the RTSP address of on the top instrument two dimensional code click play to view the screen real time projection you also can install VLC player in the mobile phone tester and mobile phone display at the same time ...

Page 34: ...deo Press enter function One key to detect all network cameras and auto play the images Auto log in and display camera image Detailed operation refer to ONVIF function After exit ONVIF app Click Refresh to search ip address ...

Page 35: ... to the same network segment with the scanned camera s IP Discovery IP Connected tester equipment s IP address If the camera connected to the tester directly tester will display the camera s IP address if tester connects to Local Area Network it displays the current IP address Temp IIP after searching IP address the modified tester s IP address will not be saved if you do not select Temp IP the mo...

Page 36: ...a image by tester mainstream one key to activate Dahua camera Press enter ONVIF function the meter auto scan all ONVIF cameras in different network segments It lists cameras name and IP address on the Left of screen Tester can auto login camera and display camera image Factory default use admin password to auto login if you modified the password then default use the modified password to log in If ...

Page 37: ... the ONVIF setting icon in the upper left corner Across network segments scan After open this function enter Setting IP Settings Advanced to add other network segments IP Rapid ONVIF function can across network segments to scan camera s IP Auto Login After open this function tester can auto login camera and display camera image The login password is the same with last time the first time using pas...

Page 38: ...iew manual Open Manual Restore Defaults Revert Rapid ONVIF to default settings Confirm Save the modified parameters Click MENU icon to open camera setting While in the Live video menu click Video Menu at the top right of the image to access the following tools Snapshot Record Photo Playback PTZ and Settings ...

Page 39: ...o move left right to go right up to go up and down to go down Compatible IP PTZ cameras will rotate accordingly PTZ rotation direction is displayed on top left corner of the image IP camera video settings Click Video Set to enter the IP camera s encoder and resolution settings Make the desired changes and click OK to save ...

Page 40: ...aging Set to adjust image brightness saturation contrast sharpness and backlight compensation mode Profiles Click profiles can view video streaming current configuration files as well as switch between Major stream and minor stream ...

Page 41: ...ures Quickly preview and zoom in or out pictures automatically and manual refresh Identification click Identification to view information of the camera Time set click Time set Select Manual set to set up the time of camera ...

Page 42: ...Page 37 Maintenance For camera software reset or restore to factory settings User Set Modify camera user name password etc parameters ...

Page 43: ...Some cameras cannot support change IP address so there is no change after saving Zoom in image press the key to enter the zoom mode Press it again to exit zoom mode When the image is enlarged tap left right up or down on the image to move the whole image on the screen ...

Page 44: ... the tester as the tester supports resolution up to 1080p the input image will be very clear after it is enlarged This is greatly helpful for the installers to ensure the IP camera s video coverage and decide the IP camera s install site Image can only be enlarged on SD mode The icon ONVIF is SD mode Select relative function on the bottom Toolbar to operate Snapshot Record Photos Video playback St...

Page 45: ...s after snapshot Record When you click bottom the Record icon video starts recording A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video Click on the Stop icon to stop recording and save the video file in the tester Playback Click the Playback icon to view saved videos Double click the video you want to play Click to return t...

Page 46: ... Set preset position Move the camera to preset position enter the preset number on the Bottom right corner to complete position preset Call the preset position Select the preset number on the left click Call to call preset PTZ Speed set Horizontal and Vertical Speed set ...

Page 47: ...address of the current camera Doc Auto create testing reports document of camera click Create document Click Preview to view the report document Enter the camera test information click Create Document to complete the report ...

Page 48: ...n icons on the bottom toolbar 3 3 9 IP camera test Display image from the 4K camera by main stream Click icon to enter IP camera test Note Currently the Test App only supports some brands specific IP cameras these include specific models made by ACTI AXIS Dahua Hikvision Samsung and many more If the camera is ...

Page 49: ...k on the IP Camera type to select the Manufacturer and model number of the integrated IP camera Manual Click IP camera type list Honeywell Kodak Tiandy Aipu waton ACTi WoshiDA IP camera etc If the brand has offered official original protocols pls select camera type input IP camera address user name and password click official to enter the camera image display interface Currently only support DAHUA...

Page 50: ...camera s IP address It is better to directly connect the IP camera to the tester so the search results will only display the camera s IP address If the tester is connected to a PoE switch it will find and display several IP address IPC User Name Enter IP camera s user name IPC Password Enter IP camera s login password IPC Port When you select the IP camera type it will default the camera s port nu...

Page 51: ... Tap icon to enter When tester receives HDMI in image the top tool bar shows the resolution of this image You can select resolution to set resolution in the setting menu Tap screen by twice full image display Support resolution below 720 480p 720 576p 1280 720p 1920 1080p 1024 768p 1280 1024p 1280 900p 1440 900p 1 Snapshot Click the icon Snapshot when the video in to take a picture and save the cu...

Page 52: ...ars indicating the time elapsed for the video Click on the Record icon again to stop recording and save the video file in the tester If select manual storage before recording begins appears dialog box Input Name user defined the files name by Chinese character English letter or digit to store in the tester tester will hereby store the files after recording ...

Page 53: ...e image can view full screen Double click again the photo to return To rename or delete an image click and hold on the file until this screen below appears Click to close and return to PTZ controller 4 Recorded video playback Click the Playback icon to view your recorded videos Tap on the video file image you want to watch ...

Page 54: ...ename or delete a video click and hold on the file until this screen appears Video files also can play in the main menu Video Player 3 3 11 Video monitor test Analog camera test and PTZ control click icon to enter ...

Page 55: ...LOR BURST measurement Select relative function on the right side Toolbar to operate functions including Photos Snapshot Record Playback PTZ Set Click or press to quit Click the screen twice quickly can be full zoom in on the touch screen 1 PTZ controller parameter setting Select and click icon PTZ to enter PTZ setting ...

Page 56: ...dome address E Pan speed Set the pan speed of PTZ camera 0 63 F Tilt speed Set the tilt speed of PTZ camera 0 63 G Set preset position Set PS Click and select Set PS set and save preset position number 1 128 H Call the preset position Go ps Click and select Set PS set and save preset position number 1 128 click sure to save Call some special preset number can call the dome camera menu Check and se...

Page 57: ...lor saturation as well as the file storage way after snapshot and recording support auto storage and manual storage When select manual storage user can name and store the files 3 4 x zoom image display and Video out When image input press to enter zoom press it again to quit Using the touch screen to control PTZ camera movement Tap left right upward or downward on the video image to move the PTZ c...

Page 58: ... video input as it supports resolution up to 1280 960 the zoom in image is still very clear This is very helpful for IP camera installation 4 Snapshot Click the icon Snapshot when the video in to take a picture and save the current video frame in the tester as JPEG file If the unit is set to the manual mode an Input Name pop up box will appear and you can enter a title for the snapshot If the unit...

Page 59: ...torage before recording begins appears dialog box Input Name user defined the files name by Chinese character English letter or digit to store in the tester tester will hereby store the files in the tester after recording if select Auto storage tester will auto store the files in the tester after recording 6 Photo Click the icon photo to enter click the selected thumbnail photo to display it on th...

Page 60: ...is screen below appears Click to close and return to PTZ controller 7 Recorded video playback Click the Playback icon to view your recorded videos Tap on the video file image you want to watch To rename or delete a video click and hold on the file until this screen appears ...

Page 61: ... speed sampling and processing technology can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK SYNC levels and COLOR BURST chroma level When an analog signal is fed into the meter the tester displays the measurements on the bottom left corner of the screen While in PAL format the unit will be mV While in NTSC format it will be IRE ...

Page 62: ...out properly If the level is too high it will lead to a poor quality image COLOR BURST level Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image For NTSC format the Chroma standard level i...

Page 63: ...VIDEO IN port the signal send via VIDEO OUT port and received via VIDEO IN port If the testing is ok the tester displays several gradually dwindling photos on the desktop 3 3 12 Color bar generator TV OUT Click to enter the tester sends the color bars from the Video out port Click the icon PAL select PAL NTSC output formats Click the selected color bars testing image or single bar red green blue w...

Page 64: ...or bar by its BNC output to the monitor at the monitoring center If the monitor receive the color bar it means the video transmit channel works normally Meanwhile on the basis of the received color bar the monitoring center can judge if transmission has loss or interference B The tester sends out the pure color bar such as white and black color to test the monitor whether has bright or black dots ...

Page 65: ...0x1080P 25Hz 1920x1080P 30Hz 1920x1080I 50Hz 1920x1080I 60Hz The tester s HDMI output port can be used as SDI to HDMI converter output HD SDI image to HD TV monitor Select relative function on the right side Toolbar to operate Snapshot Record Photos Video playback PTZ control Video Brightness and Storage set the operation is the same to the video monitor function please refer to the relevant instr...

Page 66: ...he top bar Double taps on the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x720P 30FPS 1280x720P 50FPS 1280x720P 60FPS 1920x1080P 25FPS 1920x1080P 30FPS 2560x1440P 25FPS 30FPS 1 PTZ control 1 1 Coaxial PTZ control Click the icon PTZ on the right toolbar to do the corresponding setting Port select coaxial control ...

Page 67: ...etting Operation instructions please refer to 3 3 1 PTZ 1 Video monitor test The PTZ address in the tester must be consistent with the dome camera or decoder then the tester can test After setting the parameter the tester can control the PTZ and lens ...

Page 68: ...zoom in and out the PTZ To control PTZ by key buttons Press arrow keys to control to control the PTZ direction of rotation Press the key to switch on or turn off the aperture Press the key adjust the focus manually Press the key manually adjust the zoom Set preset position Setup preset position move the PTZ camera to the preset position then Tap it and input preset position number Tap Set position...

Page 69: ...Page 64 Call preset position Tap the preset position Tap the preset position area input preset position number Tap call position to complete call preset position ...

Page 70: ...1 PTZ control parameters setting 2 Coaxial camera menu setting Tap icon UTC select menu setting to enter the dome camera menu Input calling dome camera menu address code after finishing the parameter settings you can press the key or click the icon to call the dome camera menu ...

Page 71: ...Page 66 Press arrow keys to set 3 Snapshot record photo viewer and video play back please refer to 3 3 1 PTZ 1 Video monitor test ...

Page 72: ...ve setting Click icon Set on the right toolbar to enter storage setting Support auto storage and manual storage When select manual storage user can name and store the files 3 3 15 TVI camera test HD TVI camera TVI dome camera test and PTZ control Click icon to enter ...

Page 73: ...to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x720P30FPS 1280x720P 50FPS 1280x720P 60FPS 1920x1080P 25FPS 1920x1080P 30FPS 1920x1080P 50FPS 1920x1080P 60FPS 2048x1536 18 FPS Coaxial camera menu settings Tap icon UTC select menu setting to enter the dome camera menu ...

Page 74: ...press the key or click the icon to call the dome camera menu More operation instructions such as PTZ control coaxial camera menu setting snapshot recording and playback etc please refer to 3 3 6 CVI camera test 3 3 16 AHD camera test AHD camera AHD dome camera test and PTZ control Click icon to enter ...

Page 75: ...n the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x720P 30FPS 1920x1080P 25FPS 1920x1080P 30FPS 2560x1440P 15FPS 25FPS 30FPS 1 Coaxial PTZ control UTC control select PTZ control or PTZ control 2 AHD camera has two different order if select ...

Page 76: ...ns please refer to 3 3 6 CVI camera test 3 3 17 Network tool 1 IP address scan Connect the cable to the LAN port click icon to enter Set your IP address search range by changing the Start and End IP addresses Click the Start button to scan the IP address range You can also input an IP address in the Port Number Scan to scan for open ports ...

Page 77: ...ill say Destination host unreachable or have 100 packet loss If the tester connects to the device the send and receive packets will have a 0 packet loss Application PING testing is the most conventional network debugging tools It is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct It s normal that the first dat...

Page 78: ...gment a Start the server Click Start Server button to use the tester as a Server It will display its IP address at the top of the screen b Start send packet test Using the other tester type in the Server s IP address at the top right corner of the screen This app is used to send packets for network speed testing Click the Start button to send the packets and start testing ...

Page 79: ...er as a test Client or Server to do the mutual testing with the tester If use computer as the server the computer IP address is 192 168 0 39 Tester as Client tester s IP address is 192 168 0 238 The Server and the Client are at the same network segment but with different IP address Input Server s IP address 192 168 0 39 in the tester and click Start to test network bandwidth ...

Page 80: ...Page 75 Or use tester as a Server computer as test Client select Client input tester s IP address to test When use tester as Server shows results ...

Page 81: ...oE switch are connected well the LAN port of POE switch flash at special frequency If not no any changes on the LAN port Application The tester will send special signals to make the connected LAN port flicker at special frequency which will enable the installers to easily and quickly find the connected Ethernet cable This function can prevent mistakenly insertion or disconnection non corresponding...

Page 82: ...IP cameras and other networked devices Click the Refresh button to check your Client list 6 Trace route It is used to determine path of the IP packet access target Note Trace route testing results only for reference for accurate test route tracking Pls use professional Ethernet tester Click to enter trace route Input tracking IP address or domain name in the Remote Host IP Set maximum hop count no...

Page 83: ...icts Click Add and enter the desired IP address To test different network segments click the Settings icon on the main menu and go to IP Settings and make the desired changes Once the desired IP addresses are added to the Link Monitor list click Start If the IP address status shows a check mark the IP address is occupied If the IP address status shows an X the IP address is available Click Stop to...

Page 84: ...ole network segment Click Stop to stop work 3 3 19 PoE power DC12V 2A and DC 5V 2A USB power output When the tester is turned on the 12VDC and 5VDC power output functions are automatically turned on If the tester is turned off the 5VDC USB can still be used to power an external USB device To use the PoE Power Output function click on the icon and change the switch ON or OFF The IP camera needs to ...

Page 85: ...mode Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester 4 Before turning on the PoE power output please make sure the IP camera supports PoE power Otherwise it may damage the IP camera 5 Make sure you plug in your IP camera to the LAN port prior to turning on PoE power 6 Make sure the tester is full charged or more than 80 charged other...

Page 86: ... of the cable tester kit will be displayed If need several different number other types cable testers should pay the additional cost Cable test Tap cable test sketch map pop up Straight through cable and crossover cable skectch It is for line sequence reference when the crystal on the first pressure in the twisted pair 3 3 21 RJ45 cable TDR test Connect cable to tester s LAN port click icon to ent...

Page 87: ...rcuit can test the cable length if screen display online the testing result would be not accurate Cable quality test Green is good quality cable Yellow is Poor quality cable Red is water poured cable the attenuation value will be displayed when cable over 10 meters Advanced Test test cable pair status length attenuation reflectivity impedance skew and other parameters Attenuation reflectivity afte...

Page 88: ...ink up when skew value is 0ns it is the best quality communication if over 50ns will cause a Bit Error Rate in the transmission Connection diagram Cable sequence diagram A straight through and cross over cable diagram the cable sequence display for reference ...

Page 89: ...ick icon to enter click the Number on the screen to adjust audio type Use the blue Combination cable identifier and network cable tester s copper pointer to touch all the cables in the bundle You are searching at the other end The cable that gives off the loudest tone is the cable connected to the tester Press the or buttons on your blue cable identifier to adjust the volume ...

Page 90: ...alligator clips to the copper core or copper net of the BNC cable the other one to connect the earth wire barred windows Note The battery of the cable tracer must according to corresponding positive pole and negative pole otherwise will damage the tester Note While the cable tracer tester is receiving the audio signal from the tester it may be influenced by other signals and make some noise 3 3 23...

Page 91: ... Click Cable Type to select cable and start testing One tap on Start do one testing If select built in cable type for testing click and to adjust cable s wave speed User defined calibration Choose the cable 100 meters to 200 meters more than 50 meters click Cable Type to select user defined 1 for calibration 11 groups user defined can be set ...

Page 92: ... 3 Click or to adjust wave speed while display length is the same with the actual Length click Save to save calibration data It can be used for the same cable testing next time Application TDR test is used for pulse reflection method to transmit pulse signal for tested cable when cable is open circuit or short circuit reflected pulse is generated the tester receives and deals with the reflected wa...

Page 93: ...tch to the tester s PSE IN port Connect an IP camera or other PoE using node to the tester s LAN port the PoE voltage and the cable s pin connection status show on the screen Note This test if for measuring the voltage being drawn by the PoE node and the tester must be between the PoE switch and the PoE node for this test to work Note The PoE switch must be connected to the PSE IN port The powered...

Page 94: ...input test Connect 12V power adaptor to tester s charging port then click icon PoE to enter voltage measurement app screen show the current adaptor input voltage and power Note the current 12V input measured power is the battery charging power and the device working power the measured power will change depending on the different of battery power and backlight brightness Warning Not allow connect d...

Page 95: ...easurement state display Auto range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative measurement Display the relative measurement value Press the key to change display state 10A socket In 10A current measurement state indicate use 10A socket Over range The current measurement value over the range if in the Auto range state to switch Auto 2 OPER...

Page 96: ... select U enter the AC voltage measurement C the tester default Auto range status by click AC auto range d Manual range can be select press the key NEAR to restore Auto range e Manual range 0 000V 6 600V range 00 00V 66 00V range 000 0V 660 0V range 000 0mV 660 0mV range WARNING You can t input the voltage which more than DC 660V it s possible to show higher voltage but it s may destroy the inner ...

Page 97: ...When only the figure OL is displayed it indicates over range situation and the higher range has to be selected When the value scale to be measured is unknown beforehand set the range selector at the highest position The maximum current of mA socket is 660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and ...

Page 98: ...own beforehand set the range selector at the highest position The maximum current of mA socket is 660mA over current will destroy the fuse and will damage the meter The maximum current of 10A socket is 10A over current will destroy the meter and will damage the operator In AC mode only can input AC if not will damage the meter E Resistance Measuring a Connect the black test lead to the COM jack an...

Page 99: ... under testing c If continuity exists i e resistance less than about 50Ω built in buzzer will sound G Diode Testing a Connect the black test lead to the COM jack and the red test lead to the V Ω jack the red lead anode b to select enter the diode testing c Connect test red lead across to the anode the black lead to the cathode of the diode under testing WARNING When testing the circuit continuity ...

Page 100: ...e 0 000nF 6 600nF range 00 00nF 66 00nF range 000 0nF 660 0nF range 0 000uF 6 600μF range 00 00uF 66 00μF range 000 0uF 660 0μF range 0 000mF 6 600mF range 00 00mF 66 00mF range d Before connect test leads across two sides of the capacitor under measurement be sure that the capacitor has been discharged fully Note a The capacitance of a capacitor should be tested separately should not test in the ...

Page 101: ... Relative to enter the tester Auto save the data the displayed new measurement and relative value is red color Press it again to quit The hold function and the relative value be combined use the display value is yellow The meter protection Voltage protection You can t input the voltage which more than AC 660V it s possible to show higher voltage but it s may destroy the inner circuit Resistance Co...

Page 102: ...tical power testing and Fiber link loss relative measurement It is necessary tool for installation and maintenance optical fiber communication cable television and CCTV security system Note Please keep the fiber connector and the dust cap be clean and clean the detector with the special alcohol Data hold While testing click Hold to data hold the data will not change It s convenient to read Press a...

Page 103: ...layed new measurement and relative value is red color Press it again to quit Data hold and Relative measuring use together the data is yellow while the function is effect 3 3 28 Visual Fault Locator Click icon to enter ...

Page 104: ...Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to enter pulse mode click button Time off VFL is turned off Timed turn off can select 5 mins 10 mins 30 mins 60 mins and 120 mins Click Steady mode red laser source emits steady click again to quit ...

Page 105: ... certain frequency press it again to quit 3 3 29 Audio Record Connect an audio device to the Integrated Mount Tester s audio input port Click the icon to enter the Audio Recorder app Click the red button to stop and the unit will prompt you to save the recording 3 3 30 Data monitor Pls click icon to enter ...

Page 106: ...port display the PTZ control code of the multifunctional keyboard or the DVR Controller can check the status of the RS485 transmission through the code on the display The RS485 communication rate must be the same Application Check the RS485 communication states of the video optical transmitter whether normal Engineer can analyze the protocol and check the data through the displayed code 3 3 31 Aud...

Page 107: ... file name for a few seconds until the screen below appears You can then rename or delete the file by pressing the desired option 3 3 33 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera If you were unable to view your camera via the ONVIF or the Test apps it is possible your camera will have an RTSP stream and you can view live video From the main menu...

Page 108: ...e Enter the IP camera s user name IPC Password Enter the IP camera s password Once you have entered all the necessary information select Enter at the bottom left to view the RTSP stream Note In the event the Integrated Mount Tester does not auto detect the rtsp stream refer to the specific camera manufacturer for the specific rtsp stream url you may find this on line with a search of the camera mo...

Page 109: ...y image from the Hikvision camera Tap icon to enter 1 Hikvision activation When connect the unactivated Hikvison camera to the tester it will auto identify and display Unactivate at safety mode Select needed activate the camera click bottom right corner button Enable pop up the camera is not activate activate now 2 Input password Input new password tap ok to activate ...

Page 110: ... IP Activated multiple cameras in the local area Network and pop up menu to modify IP improve project efficiency Play Display image from the camera Modify network information Change the camera IP address sub net mask and gateway etc Modify user information Modify the camera s user name and password ...

Page 111: ...Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera it can display image and modify IP user name and password etc Making Dahua camera test more convenient and quickly Click DH icon to enter Dahua test tool ...

Page 112: ... 107 Select the camera of the online detection menu if the camera support non verification login you can click play directly and view the image Pop up stream menu select mainstream or second stream to test ...

Page 113: ...line detection menu and input correct user name and password then click log in After logging successful you can test it Play select mainstream or seconded stream IP camera live video display Modify network information modify camera parameter such as ip address subnet mask gateway etc ...

Page 114: ...nd password which is onvif Dahua test tool the tester user name and password not web user name and password Factory reset setting camera will be soft reset and the device s user name password and network set be saved Other settings information is factory reset ...

Page 115: ...the SD card or select Online Update to check for updates on the internet If there are applications that need updating the applications will be displayed on the screen If there are update programs applications will be listed in the interface click related applications update to the latest version Update online Before using online update need enter settings user management to register first ...

Page 116: ...intenance in the evening or in the dark Click icon to enter While in the flashlight app click the red button to turn on the LED lamp Press it again to turn it off If you don t press the red button to shut off the lamp and press the button to exit the app the lamp will stay on Click the Time Setting button to set a timer that will shut off the lamp ...

Page 117: ...camera and the tester be on the same network segment for the browser to interface with the camera If they are not in the same segment click the button or press RETRUN to exit Open the Settings app from the main menu to change the IP tester s network settings to match those of the IP camera 3 3 40 Notepad Notepad can be used to record the important testing results click the key Save to save the con...

Page 118: ...the details Press the record bar for several seconds prompt whether delete it 3 3 41 System Setting Click icon to enter Language Select your desired language English Chinese Korean Russian Italian Polish Spanish French or Japanese Typewriting You can select typewriting or install other typewriting ...

Page 119: ...iple network segments click Advanced and then click Add to enter another IP address for the Tester After setting an advanced IP address refer to the photos above the unit can test two network segments 192 168 5 0 and 192 168 1 0 WLAN Net Turn WiFi off or on by pressing the Open the wifi button Once WiFi is turned on and click connected WIFI it will scan for wireless networks in your area ...

Page 120: ... create Wi Fi hotspot Brightness Set the desired brightness of the tester and adjust the sleep time settings Volume Set volume level SD Card Displays SD Card Capacity You can also format the SD card or unmount it before removing it FTP server Once the tester connects to a network a computer can be used to read the SD card files via FTP ...

Page 121: ...y 180 degrees This function is very convenient for the user to connect the LAN cable on the bottom of the unit without having to flip the unit itself PTZ address scan You can toggle the PTZ Address scan off or on before entering the PTZ controller app This needs to be turned on in order to use the PTZ Scan feature of the PTZ app Online Registration Online update need register first after the teste...

Page 122: ...nput your pattern to enter Modify Lock screen password you need input lock password again Select password Lock screen or pattern Lock screen to reset lock screen password After reset pattern lock screen you need to draw a new lock pattern Restore the factory settings If the tester to restore factory settings all your personal files and apps will be removed 3 3 42 File explorer Click File on the to...

Page 123: ...server You can choose internal or external SD card Other operation details Pls refer to FTP settings 3 3 43 Theme Click Theme icon to enter themes setting Desktop style you can select Lite mode or normal mode Theme ...

Page 124: ... press selected color several seconds and it will be auto deleted Theme colors include fixed order and random order and click set to save Color When set background color you can select colors from Color Phase and also can input color s RGB to set After finished color setting click set to set it as desktop or application background ...

Page 125: ...desktop background and application background Cancel Cancel current setting Picture Click Picture to select one and set as temporarily background to view setting effect Click more to select pictures from local file and click set to set picture as background Sliding effect Tester s sliding effect includes stereo effect folding effect Left and right folding rotate effect Ombre ...

Page 126: ...audio pickup devices by connecting the audio pickup device to the tester with the supplied audio cable 3 5 HDMI output The built in HDMI output port can output live video from an analog or IP camera recorded files media files and images to HDTV monitors Connect an HDMI cable from the tester to an HDTV monitor at any time It supports up to 1080P resolution ...

Page 127: ... Lan port is straight line cable and has no short circuit otherwise will damage the tester b Before using PoE power output pls check the IP camera whether supports POE powered Otherwise it will damage the IP camera c The instrument s PoE maximum power output is 24W If Ultra high power load happens the tester will enter protection mode 3 7 DC12V 2A power output When the IPC tester is turned on the ...

Page 128: ...ester will automatically enter a protection mode d Disconnect all cables from the tester and reboot it to resume using the tester The tester s power output is close to 2A if the IP camera s power is over 2V the tester will auto enter protection mode Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester e Make sure the tester has a sufficie...

Page 129: ...ecoding 4K H 264 camera image display by mainstream testing IP discovery auto scan the whole network segment camera IP Rapid ONVIF search camera quickly auto log in and display image from the camera activate Hikvision camera Hik test tool Activate Hikvision camera display image from the camera modify IP user name and password parameters etc DH test tool Dahua camera test modify IP user name and pa...

Page 130: ...nt images and record live video as JPG file Media player will view photos and playback video HDMI IN HDMI IN Support 720 480p 720 576p 1280 720p 1920 1080p 1024 768p 1280 1024p 1280 900p 1440 900p HDMI output 1 channel HDMI output supports up to 1080p RJ45 cable TDR test RJ45 cable TDR test and cable quality test to test cable pair status length attenuation reflectivity impedance skew and other pa...

Page 131: ...a s IP address on your network Cable tracer Find a connected cable from a bundle of cables using audio tones PoE PSE voltage test Measures PoE switch voltage and displays pin configuration Digital Multi meter AC DC Voltage AC DC current Resistance Capacitance Data hold Relative measurement Continuity testing Testing speed 3 times seconds Data range 6600 6600 Optical power meter Calibrated Waveleng...

Page 132: ... 6600 Conversion rate 3times s Current modes for clamp meter with ZERO function Isolation the Multi meter connector must be isolated with the other connector DC voltage Range Accuracy Resolution 660mV Manual range 0 3 4 0 1mV 6 600V 1mV 66 00V 10mV 660 0V 100mV AC voltage Range Accuracy Resolution 660 0mV Manual range 1 5 6 0 1mV 6 600V 0 8 6 1mV 66 00V 10mV 660 0V 100mV ...

Page 133: ...t Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 00A 1 5 10mA Resistance Range Accuracy Resolution 660 0Ω 0 8 5 0 1Ω 6 600KΩ 0 8 2 1Ω 66 00KΩ 10Ω 660 0KΩ 100Ω 6 600MΩ 1KΩ 66MΩ 1 2 5 10KΩ Continuity Range Resolution Function 660 0Ω 0 1Ω The measurement value less 30Ω 3Ω the tester will sound ...

Page 134: ... 5 8 10pF 660 0nF 100pF 6 600μF 1nF 66 00μF 10nF 660 0μF 5 8 100nF 6 600mF 1μF 66 00mF 10μF 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavelength nm 850nm 1300nm 1310nm 1490nm 1550nm 1625nm Detector InGaAs Uncertainly 3 dB 10dBm 22 5 dB full range 22 Display Resolution Linear 0 1 Nonlinear 0 01dBm Operating Temperature 10 55 Storage Temperature 20 70 Connector type FC PC ...

Page 135: ...on mode CW 1Hz 2Hz Measurement Range 5KM Connector FC PC exchangeable Working Temperature 10 55 Operating Temperature 20 70 The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries please feel free to call the Technical Department of our company ...

Page 136: ......